PubMed · 2014276
Hepatic iron overload: quantitative MR imaging.
Abstract
Iron deposits demonstrate characteristically shortened T2 relaxation times. Several previously published studies reported poor correlation between the in vivo hepatic 1/T2 measurements made by means of midfield magnetic resonance (MR) units and the hepatic iron content of iron-overloaded patients. In this study, the authors assessed the use of in vivo 1/T2 measurements obtained by means of MR imaging at 0.5 T using short echo times (13.4 and 30 msec) and single-echo-sequences as well as computed tomographic (CT) attenuation as a measure of liver iron concentration in 10 severely iron-overloaded patients with beta-thalassemia major. The iron concentrations in surgical wedge biopsy samples of the liver, which varied between 3 and 9 mg/g of wet weight (normal, less than or equal to 0.5 mg/g), correlated well (r = .93, P less than or equal to .0001) with the preoperative in vivo hepatic 1/T2 measurements. The CT attenuation did not correlate with liver iron concentration. Quantitative MR imaging is a readily available noninvasive method for the assessment of hepatic iron concentration in iron-overloaded patients, reducing the need for needle biopsies of the liver.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
J M Gomori, G Horev, H Tamary, J Zandback, L Kornreich, R Zaizov, E Freud, O Krief, J Ben-Meir, H Rotem. 1991. Hepatic iron overload: quantitative MR imaging.. https://doi.org/10.1148/radiology.179.2.2014276. https://pubmed.health/record/pubmed%3A2014276/hepatic-iron-overload-quantitative-mr-imaging
Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite PubMed Health by Indiciae: BibTeX · RIS.