PubMed Health⌕ Search

PubMed · 203414

An enzymatic triglyceride method that is suitable for long-term population studies.

Abstract

An enzymatic triglyceride method has been shown to be a suitable alternative to the Lipid Research Clinics' extraction/fluorometry method in long-term population studies. Correlation of results obtained with this method by this laboratory (y-axis) and by the Minneapolis Lipid Research Clinic Laboratory (x-axis) during a nine-week standardization period produced a curve with an intercept of -72 mg/liter, a slope of 1.019, and a correlation coefficient of r=0.996 (n=47). During this standardization period certain methodological problems were observed and corrected. An increase in background in certain clinical specimens, caused by spontaneous degradation of NADH, was observed, accurately measured, and taken into account when appropriate.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D F Koehler, B W Steele, M M Azar, K Kuba, M E Dempsey. 1978. An enzymatic triglyceride method that is suitable for long-term population studies.. https://pubmed.ncbi.nlm.nih.gov/203414/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Comparison of triglyceride concentration with lipemic index in disorders of triglyceride and glycerol metabolism.

BACKGROUND: In plasma, triglycerides (TG) are transported in lipoprotein particles (mainly chylomicrons, very low-density and low-density lipoprotein). Turbidimetry (bichromatically at 660 and 700 nm) allows measurement of the lipemic (L) index. We explored the use of this index, in combination with a TG assay, to detect errors due to non-fasting, to assess abnormalities in TG metabolism and to detect patients with glycerol kinase deficiency (GKD). METHODS: We collected 2441 patient samples. Normolipidemic (n=2347), type IV hyperlipidemic (n=80), postprandial samples (n=22) and serial dilutions of Intralipid with saline (n=6) were selected. One patient presenting with GKD was included, as well as two patients with type I and type V hyperlipoproteinemia, respectively. RESULTS: We introduced the use of the ratio between the logarithm of serum triglycerides and that of the L-index (TG/L ratio). CONCLUSION: Although the proposed TG/L-index ratio cannot be regarded as an alternative for the accurate diagnosis of lipid disorders, it provides additional information about TG-containing particles.

Glycerol Kinase↗

Serum triglycerides determined colorimetrically with an enzyme that produces hydrogen peroxide.

In this direct colorimetric procedure, serum triglycerides are hydrolyzed by lipase, and the released glycerol is assayed in a reaction catalyzed by glycerol kinase and L-alpha-glycerol-phosphate oxidase in a system that generates hydrogen peroxide. The hydrogen peroxide is monitored in the presence of horseradish peroxidase with 3,5-dichloro-2-hydroxybenzenesulfonic acid/4-aminophenazone as the chromogenic system. The high absorbance of this chromogen system at 510 nm affords useful results with a sample/reagent volume ratio as low as 1:150, and a blank sample measurement is not needed. A single, stable working reagent is used; the reaction is complete in 15 min at room temperature. The standard curve is linear for triglyceride concentrations as great as 13.6 mmol/L. Average analytical recovery of triglycerides in human sera is 100.1%, and within-run and between-run precision studies showed CVs of less than or equal to 1.6 and less than or equal to 3.0%, respectively. The method is suitable for automation.

Glycerol Kinase↗