PubMed HealthSearch

PubMed · 2062222

Real-time flow measurements using echo-planar imaging.

Abstract

The ultra-high-speed echo-planar imaging (EPI) method is combined with velocity encoding prior to EPI read-out, thereby allowing real-time measurement of flow. Results of EPI flow measurement experiments are presented on phantoms and human volunteers.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D N Guilfoyle, P Gibbs, R J Ordidge, P Mansfield. 1991. Real-time flow measurements using echo-planar imaging.. https://doi.org/10.1002/mrm.1910180102

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Orientation and deformation of erythrocytes in flowing blood.

The effects of flow on the changes of electrical resistivity and light-scattering characteristics of blood are experimentally and theoretically discussed. Studies indicate that most erythrocytes deform and orient themselves in the flow direction when blood flows in a conduit. Such oriented blood shows anisotropic properties. Anisotropic electrical resistivity of flowing blood is measured in three rectangular directions with a measurement cell of coaxial cylindrical type. From these experimental results, the orientation and deformation of erythrocytes are discussed. The orientation ratio and the deformation are calculated using a simplified spheroidal model of an erythrocyte. Calculated results show that the fractions of erythrocytes with their short axis parallel to each direction and the equivalent axis ratio for a simplified spheroidal model change with the shear rate of flow.

Blood Flow Velocity

Caval contribution to flow in the branch pulmonary arteries of Fontan patients with a novel application of magnetic resonance presaturation pulse.

BACKGROUND: A complete understanding of fluid mechanics in Fontan physiology includes knowledge of the caval contributions to right (RPA) and left (LPA) pulmonary arterial blood flow, total systemic venous return, and relative blood flow to each lung. METHODS AND RESULTS: Ten Fontan patients underwent cine MRI. Three cine scans of the pulmonary arteries were performed: (1) no presaturation pulse, (2) a presaturation pulse labeling inferior vena cava (IVC) blood (signal void), and (3) a presaturation pulse labeling superior vena cava (SVC) blood. The relative signal decrease is proportional to the amount of blood originating from the labeled vena cava. This method was validated in a phantom. Whereas 60+/-6% of SVC blood flowed into the RPA, 67+/-12% of IVC blood flowed toward the LPA. Of the blood in the LPA and RPA, 48+/-14% and 31+/-17%, respectively, came from the IVC. IVC blood contributed 40+/-16% to total systemic venous return. The distributions of blood to each lung were nearly equal (RPA/LPA blood=0.94+/-11). CONCLUSIONS: In Fontan patients with total cavopulmonary connection, SVC blood is directed toward the RPA and IVC blood is directed toward the LPA. Although the right lung volume is larger than the left, an equal amount of blood flow went to both lungs. LPA blood is composed of equal amounts of IVC and SVC blood because IVC contribution to total systemic venous return is smaller than that of the SVC. This technique and these findings can help to evaluate design changes of the systemic venous pathway to improve Fontan hemodynamics.

Blood Flow Velocity

Voxel sensitivity function description of flow-induced signal loss in MR imaging: implications for black-blood MR angiography with turbo spin-echo sequences.

The conditions in which the image intensity of vessels transporting laminar flow is attenuated in black-blood MR angiography (BB-MRA) with turbo spin-echo (TSE) and conventional spin-echo (CSE) pulse sequences are investigated experimentally with a flow phantom, studied theoretically by means of a Bloch equation-voxel sensitivity function (VSF) formalism, and computer modeled. The experiments studied the effects of: a) flow velocity, b) imaging axes orientation relative to the flow direction, and c) phase encoding order of the TSE train. The formulated Bloch equation-VSF theory describes flow effects in two-dimensional (2D)- and 3D-Fourier transform magnetic resonance imaging. In this theoretical framework, the main attenuation mechanism instrumental to BB-MRA, i.e., transverse magnetization dephasing caused by flow in the presence of the imaging gradients, is described in terms of flow-induced distortions of the individual voxel sensitivity functions. The computer simulations predict that the intraluminal homogeneity and extent of flow-induced image intensity attenuation increase as a function of decreasing vessel diameter, in support of the superior image quality achieved with TSE-based BB-MRA in the brain.

Blood Flow Velocity