PubMed HealthSearch

PubMed · 2079069

Estimation of errors in mechanical efficiency.

Abstract

Errors in measurements of mechanical work, net energy expenditure and mechanical efficiency (ME) were calculated, when subjects performed isolated eccentric or concentric muscle actions and combinations of these actions [stretch-shortening cycle (SSC) exercises] with a special sledge apparatus. The relative error of mechanical work was 6.1%. When estimating the error of energy metabolism from oxygen consumption the error would be about 4% (McArdle et al. 1981). The maximum error of ME was the sum of these two values (10.1%). Obviously the error of ME was less than 5%, because 30 muscle actions were averaged and, in addition, the errors of mechanical work and energy expenditure were not in the same direction every time. It was concluded that mechanical work can be determined accurately when the force is measured as a function of the moved distance of the sledge. Thus calculation of ME can be performed quite reliably in isolated eccentric and concentric exercises. The greatest problems were, however, in the SSC exercises, where the errors were higher, because of the problems of dividing the net energy expenditure into eccentric and concentric phases. Therefore, further developments must be made to minimize the errors in measurement and calculation during SSC-exercise.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P Oksanen, H Kyröläinen, P V Komi, O Aura. 1990. Estimation of errors in mechanical efficiency.. https://doi.org/10.1007/bf00236070

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A simple model for the function of proteoglycans and collagen in the response to compression of the intervertebral disc.

The nucleus pulposus of the intervertebral disc exerts a pressure which enables it to support axial compression when contained by the annulus fibrosus. The disc was modelled as a thick-walled cylindrical pressure vessel in which the nucleus was contained radially by the annulus. As a result, the stress in the annulus had radial (compressive) as well as tangential (tensile) components. The radial stress at a given point in the annulus was considered to be balanced by the internal pressure which is expected to arise from the attraction of water by proteoglycans. There was a reasonable agreement between the calculated radial stress distribution and published results on the distribution of water within the annulus. As the internal pressure is expected to be isotropic, the annulus was expected to contribute to the axial resistance to compression of the disc; this contribution would be equal, in magnitude, to the radial stress. Predictions of the pressure distribution within the annulus were similar to published experimental measurements made in the radial and axial directions. The tangential stress within the annulus was considered to arise from the restoring stress in its strained collagen fibrils.

Biomechanical Phenomena

Flow-induced prostacyclin production is mediated by a pertussis toxin-sensitive G protein.

Fluid flow and several other agonists induce prostacyclin (PGI2) production in endothelial cells. G proteins mediate the response of a large number of hormones such as histamine, but the transduction pathway of the flow signal is unclear. We found that GDP beta S and pertussis toxin inhibited flow-induced prostacyclin production in human umbilical vein endothelial cells. In addition, flow potentiated the histamine-induced production of PGI2. This suggests that flow stimulates prostacyclin production via a pertussis toxin-sensitive G protein and modulates the stimulus-response coupling of other agonists.

Biomechanical Phenomena