PubMed HealthSearch

PubMed · 2101542

Force platform for stabilographic studies.

Abstract

An analysis is made in the paper of a triangular force platform included in a computer system for postural analysis using Pravets 8M personal computer. The tensions generated in steel rings in the three corners of the platform, proportional to the moments of the forces with spontaneous fluctuations of the position of the centre of the force exercised by the experimental subject on the platform, are registered and amplified using three identical amplifying channels comprising tensotransducer, preamplifier and second-order low-frequency filter. The output signals of the three amplifying channels are fed to an analogue decoder generating an electrical signal proportional to the weight and to the anterior-posterior and lateral components of the force. The signals from the outputs of the decoder can be used for introducing visual feedback about postural stabilization. The regulations of the platform are maximally simplified so as to be used in clinical research.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Vankov, S Dunev, S Videnov. 1990. Force platform for stabilographic studies.. https://pubmed.ncbi.nlm.nih.gov/2101542/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Description and demonstration of a CMOS amplifier-based-system with measurement and stimulation capability for bioelectrical signal transduction.

An extracellular recording system incorporating an electrode array and an amplifier/stimulator CMOS chip is described and characterized. Important features of this custom VLSI chip include 16 instrumentation amplifiers with a gain of 50 and the incorporation of a cross-point array allowing designation of an extracellular microelectrode as either a stimulator or sensor. The planar array consisted of 32 microelectrodes, 14 microns in diameter, and four larger reference electrodes. Microelectrodes, interconnecting traces, and bond pads were patterned with a 500-nm layer of gold. The interconnecting traces were passivated with a 1-micron thick layer of silicon nitride to provide chemical and electrical insulation and microelectrode impedance was lowered utilizing electrode position of platinum black. The amplifier exhibited a nearly flat frequency response with high pass and low pass corner frequencies of 0.7 Hz and 50 kHz, respectively. The input referred noise over the 50 kHz bandwidth was 12-16 microVRMS, well below the magnitude of previously reported extracellular potentials. Crosstalk between neighboring channels resulted in an output signal below the amplifier noise level, even for relatively large extracellular potentials. Using this system, extracellular recording were demonstrated yielding typical peak-to-peak biopotentials of magnitude 0.9-2.1 mV and 100-400 microV for chick cardiac myocytes and rat spinal cord neurons, respectively. The key components of this extracellular recording system can be manufactured using industry standard thin film photolithographic techniques.

Amplifiers, Electronic

Design parameters of pulsed wave ultrasonic Doppler blood flowmeter.

Pulse wave Doppler techniques promise the ability to make more effective measurements of dynamic cardiovascular functions. Quantitative measurement of blood flow can be achieved by using the pulse wave Doppler system. This paper discusses the design parameters of the pulse wave Doppler blood flowmeter (PW Doppler) with respect to the physiological system.

Amplifiers, Electronic

Beamformed nearfield imaging of a simulated coronary artery containing a stenosis.

This paper is concerned with the potential for the detection and location of an artery containing a partial blockage by exploiting the space-time properties of the shear wave field in the surrounding elastic soft tissue. As a demonstration of feasibility, an array of piezoelectric film vibration sensors is placed on the free surface of a urethane mold that contains a surgical tube. Inside the surgical tube is a nylon constriction that inhibits the water flowing through the tube. A turbulent field develops in and downstream from the blockage, creating a randomly fluctuating pressure on the inner wall of the tube. This force produces shear and compressional wave energy in the urethane. After the array is used to sample the dominant shear wave space-time energy field at low frequencies, a nearfield (i.e., focused) beamforming process then images the energy distribution in the three-dimensional solid. Experiments and numerical simulations are included to demonstrate the potential of this noninvasive procedure for the early identification of vascular blockages-the typical precursor of serious arterial disease in the human heart.

Amplifiers, Electronic