A continuous fluorimetric assay for ATPase activity.
Abstract
A new continuous coupled fluorimetric assay is described for ATPases in general. Thus phosphate released from ATP hydrolysis is coupled to the nucleoside phosphorylase reaction using 7-methylguanosine as a fluorescent substrate for the nucleoside phosphorylase reaction. The hydrolysis of 7-methylguanosine leads to 7-methylguanine, which has lower quantum yield and hence can be used to monitor ATP hydrolysis continuously. The method has the potential to be extended to GTPase and nucleotidyltransferase assays.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
U Banik, S Roy. 1990-03-01. A continuous fluorimetric assay for ATPase activity.. https://pubmed.ncbi.nlm.nih.gov/2138458/