PubMed Health⌕ Search

PubMed · 2205976

The radiation phosphene.

Abstract

A low flux of X-rays below the Cerenkov energy threshold generates a phosphene by direct action on the retina without a fluorescence in the ocular media. X-rays above the Cerenkov threshold can generate only a faint luminescence in the lens and cornea. From experimental work on humans in 1905 with unencapsulated radium, it is known that approximately 80% of the intensity of the radium phosphene is from the beta-ray component and approximately 20% from the gamma-ray. From calculations of the photon yield due to Cerenkov radiation in the eye from radium, one finds intensities of approximately 90% and approximately 10% for beta and gamma-rays, respectively, if only Cerenkov radiation is considered. Thus, one may conclude that the dominant mechanism of the radium phosphene is Cerenkov radiation, primarily from electrons and not fluorescence as previously speculated. The term "radium phosphene" is a misnomer and should be subsumed along with the X-ray phosphene and particle induced visual sensations under the name "radiation phosphene".

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K D Steidley. 1990. The radiation phosphene.. https://doi.org/10.1016/0042-6989(90)90171-g

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Optimal designs for radiation retention with poisson correlated response.

In this paper we describe a non-linear model with correlated observations which accounts for the elimination rate of radiation in the lung of individuals who have been exposed to an accidental intake at some time. The response is then modelled as a conditional Poisson distribution. When the leak is moderate or the size of the particles is large a theoretical justification of this assumption is given and D-optimal designs are computed.

Dose-Response Relationship, Radiation↗

Nanodosemeters based on gel scintillators.

The feasibility of a nanodosemeter based on a liquid scintillator cocktail of four components (ethoxylated nonylphenol, pseudocumene, water and a lipophilic mixture) is studied. The dosemeter can work in distinct gel phases, for which the radioactive substance can be confined inside aqueous nanoscale structures of different size. For water volumes ranging 0-15%, it results in a gel with micelles of 4 nm radius. For water volumes ranging 30-50%, the resulting liquid-crystal gel contains nanostructures of approximately 20 nm radius. The low-energy electron emission arising from the decay of (3)H and (55)Fe is counted in a commercial liquid-scintillation counting spectrometer for both homogeneous and gel samples. The counting efficiency gap between the two phases is used to compute the average energy deposited inside the micelle.

Dose-Response Relationship, Radiation↗

Stereotactic radiosurgery and radiation therapy for spinal tumors.

Spinal tumors constitute 15% of all CNS neoplasms. Radiation therapy can be administered for palliation of pain and spinal cord compression. However, the amount of radiation that can be administered is often limited by the tolerance of the spinal cord, especially in cases where prior radiation therapy has been given. Stereotactic radiosurgery and radiotherapy allow the delivery of a higher dose of radiation to spinal lesions, while limiting the spinal cord dose to below the tolerance level. These are technically demanding procedures and should be performed only when proper equipment and expertise are available. Data on spinal stereotactic radiosurgery and radiotherapy have emerged in recent years. This review summarizes the clinical applications of stereotactic radiosurgery and radiotherapy for spinal tumors.

Dose-Response Relationship, Radiation↗