PubMed Health⌕ Search

PubMed · 2208698

A noninstrumented quantitative test system and its application for determining cholesterol concentration in whole blood.

Abstract

A novel noninstrumented technology has been developed for quantifying analytes of clinical interest in biological fluids. Application of this technology is exemplified by the development of a quantitative cholesterol test with performance equivalent to state-of-the-art instrumented methods. The assay chemistry combines two separate processes located in different areas of a test strip: enzymatic action on serum cholesterol to produce hydrogen peroxide (5 x 10 mm enzyme reagent pad) and quantification of the hydrogen peroxide (5 x 70 mm measurement region). Color bands are formed in the measurement area through the use of a redox-coupled indicator system. The height of the color band on the strip is directly proportional to the sample cholesterol concentration. A one-step cassette contains all components necessary to run the test and includes blood filtration and automatic sample measurement, so that unmeasured finger-stick whole-blood specimens can be analyzed by the non-technically trained user. The test is complete in less than 15 min, is read visually like a thermometer, and gives results that are in excellent correlation with established instrumented methods.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M P Allen, A DeLizza, U Ramel, H Jeong, P Singh. 1990. A noninstrumented quantitative test system and its application for determining cholesterol concentration in whole blood.. https://pubmed.ncbi.nlm.nih.gov/2208698/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Therapeutic drug monitoring of tacrolimus with the dried blood spot method.

In a preliminary investigation an assay for tacrolimus based on fingerprick sampling and consecutive application as a blood spot on sampling paper has been developed. The dried blood spot was analysed by HPLC-tandem mass spectrometry. The validated range was 1-30 microg/l. Intra- and inter-assay variability for precision and accuracy was <7.5% and 15%, respectively. Tacrolimus concentrations of 24 stable out patients were compared after both blood spot sampling and conventional venous sampling. Method agreement was investigated with the methods of Passing and Bablok and Bland Altman and proved suitable for clinical use. The dried blood spot method for tacrolimus seems promising for patient monitoring.

Blood Specimen Collection↗