PubMed Health⌕ Search

PubMed · 2225837

Dialysis hypotension.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Q Maggiore, S Nigrelli, T Cerrai. 1990. Dialysis hypotension.. https://doi.org/10.1159/000418283

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

What is uremia? Retention versus oxidation.

The uremic syndrome is characterized by the retention of a host of compounds which in healthy subjects are secreted into the urine by the healthy kidneys. These compounds disturb many physiologic functions, resulting in toxicity. However, many of the retained compounds as well as many of the pathophysiologic actions of the known retention solutes remain unknown. In this publication, we review recent information on uremic toxicity. Especially the difficulty to remove compounds, such as protein-bound compounds and larger molecules, seems to play a crucial role. New strategies enhancing their removal might be highly useful. Part of the retained compounds are the result of oxidative processes due to the inflammatory status of uremic patients; however, other compounds are not, and even the concentration of oxidative compounds will be further increased by disturbances of urinary clearance.

Hemodialysis Solutions↗

[Determination of the dose of dialysis with integrated modules in the same monitor].

The "gold standard" method to measure the mass balance achieved during dialysis for a given solute is based on the total dialysate collection. This procedure is unfeasible and too cumbersome. For this reason, alternative methods have been proposed including the urea kinetic modelling (Kt/V), the measurement of effective ionic dialysance (Diascan), and the continuous spent sampling of dialysate (Quantiscan). The aim of this study was to compare the reliability and agreement of these two methods with the formulas proposed by the urea kinetic modelling for measuring the dialysis dose and others haemodialysis parameters. We studied 20 stable patients (16 men/4 women) dialyzed with a monitor equipped with the modules Diascan (DC) and Quantiscan (QC) (Integra. Hospal). The urea distribution volume (VD) was determined using anthropometric data (Watson equation) and QC data. Kt/V value was calculated according to Daurgidas 2nd generation formula corrected for the rebound (eKt/V), and using DC (Kt/VDC) and QC (Kt/VQC) data. The total mass of urea removed was calculated as 37,93 +/- 16 g/session. The VD calculated using Watson equation was 35.7 +/- 6.6 and the VDQC was 35.06 +/- 9.9. And they showed an significative correlation (r:0,82 p < 0.001). The (VDQC-VDWatson) difference was -0.64 +/- 5.8L (ns). Kt/VDC was equivalent to those of eKt/V (1.64 +/- 0.33 and 1.61 +/- 0.26, mean difference -0.02 +/- 0.29). However, Kt/VQC value was higher than eKt/V (1.67 +/- 0.22 and 1.61 +/- 0.26 mean difference 0.06 +/- 0.07 p < 0.01). Both values correlated highly (R2: 0.92 p < 0.001). Urea generation (C) calculated using UCM was 8.75 +/- 3.4 g/24 h and those calculated using QC was 8.64 +/- 3.21 g/24 h. Mean difference 0.10 +/- 1.14 (ns). G calculated by UCM correlated highly with that derived from QC (R2: 0.88 p < 0.001). In conclusion, Kt/VDC and Kt/VQC should be considered as valid measures for dialysis efficiency. However, the limits of agreement between Kt/VQC and eKt/V were closer than Kt/VDC.

Hemodialysis Solutions↗