This study compared the stress distribution during insertion and function of three prefabricated endodontic posts with different designs using the criteria of post length and diameter. Test blocks of photoelastic material were prepared with simulated endodontic canals. Three posts for each design, diameter, and depth were cemented. Each specimen was examined and photographed without load, with 135 Newton (N) compressive force, and with 90 N and/or 135 N oblique force applied at 26 degrees by use of a circular polariscope. Para-Post and Para-Post Plus posts produced similar, evenly distributed patterns of stress using the criteria of diameter, depth, and load. Flexi-Post posts produced asymmetric stress patterns with concentration of stress at each thread. During compressive loading and after cementation alone, Flexi-Post posts displayed significantly higher shoulder stresses and substantially greater stresses along the coronal surface of the post's length than Para-Post and Para-Post Plus posts. Apical stresses were similar for Flexi-Post, Para-Post, and Para-Post Plus posts during compressive loading.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D A Burns, W R Krause, H B Douglas, D R Burns. 1990. Stress distribution surrounding endodontic posts.. https://doi.org/10.1016/0022-3913(90)90036-c

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Stress analyses of four prefabricated posts.

A two-dimensional photoelastic stress analysis method was applied to study the relative magnitude of stress and concentration induced by four commercially available posts for endodontically treated teeth. Three types of threaded posts; VLock, Radix Anchor, and Flexi-Post, and one nonthreaded prefabricated post, the Para-Post Plus post were tested. Stress was recorded at installation, at vertical and inclined load, and the threaded posts were compared with the nonthreaded post. At installation and on loading, stress was induced where posts were in contact with the model. Higher apical stresses were demonstrated for the Para-Post Plus post whereas the threaded posts concentrated stress where they engaged the model through threads or flanges.

Dental Stress Analysis

Investigation into the behavior of symmetrically and asymmetrically activated face-bows.

The distal and lateral forces and also the couples (in a transverse plane) delivered by the inner terminals of a face-bow have been derived analytically according to the complementary (strain) energy method for various face-bow configurations on the assumption that the terminals are rigidly held by the molar tubes and that the external forces acting are in the plane of the inner bow. The results of the theory have been checked experimentally with a specially designed apparatus in which two mild steel transducer pegs that carry three pairs of strain gauges were used to measure the force system delivered by the inner bow under a range of loading, both symmetrical and asymmetrical. Good agreement with the theory was obtained, confirming the validity of the theoretical analysis. It is concluded that force systems are dependent on bow geometry and that with increasing asymmetry of the external loading transference of the distal load to the power-arm side is accompanied by a shift of lateral force and couple to the opposite side.

Dental Stress Analysis