Monocular simultaneous refraction.

Abstract

A system was developed to give an alternative to the standard Jackson Cross Cylinder test. This system eliminates the major difficulty of the Jackson Cross Cylinder test, which is alternative viewing of the images. The advantages of this system are: 1) ease of patient choice, 2) speed of testing, 3) patient preference, and 4) ease of understanding the test. The major disadvantage of this test system was that a few patients had difficulty viewing two images. Most difficulties could be easily resolved by a variation in the examination technique. (It helped if the patients were told they would now see double, or two rows of letters.) Occasionally, patients who had a field loss found this test difficult. The second problem was similar to one encountered with the Jackson Cross Cylinder test in that some patients would report one target clearer, regardless how one changed the lens. This was overcome by turning the testing lens system over so that the testing lens on the bottom was now on the top. Recently, we have relied only on the MSR technique as our subjective refraction, and the final prescription was based on it. These patients have reported no problems and have had good acuities. The MSR technique, when tested on a large number of patients, is demonstrated to be both efficient and reliable. The simultaneous refraction technique is not meant to be used to the exclusion of all other cylinder subjective tests, but, rather as an adjunct to our standard technique when conditions warrant its use.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M L LeVine. 1990. Monocular simultaneous refraction.. https://pubmed.ncbi.nlm.nih.gov/2246468/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Paraxial optics of astigmatic systems: relations between the wavefront and the ray picture approaches.

PURPOSE: The paraxial propagation of astigmatic wavefronts through astigmatic optical systems can be described by the augmented step-along method (ASAM). Its equivalence to the linear ray optics approach is considered in detail. METHODS: The ASAM is exploited to derive paraxial ray paths through a general coaxial astigmatic system. RESULTS: Starting from the information inherent in the ASAM all 2x2 submatrices rendering the general 4x4 transference of linear optics can be generated. This proves the complete equivalence of both approaches. Additionally, we show that the symplectic relations are automatically obeyed in the ASAM. CONCLUSIONS: The ASAM offers a complete alternative to describe the paraxial optics of astigmatic optical systems. According to the ASAM, an optical system is fully characterized by the back vertex vergence and the angular magnification matrix. Hence, a complete description of the paraxial optics of an eye should not only report the state of refraction but the angular magnification matrix as well, although it is not yet very common. The magnification matrix might be important in cases of anisometropia or the design of progressive addition lenses. Yet, a simple clinical procedure to determine the angular magnification matrix is missing.

Astigmatism↗

Status of toric intraocular lenses.

PURPOSE OF REVIEW: To provide an update on the status of toric intraocular lenses. These lenses can be used as an alternative or adjunct to corneal astigmatic incisions for correcting preexisting astigmatism in patients with cataracts. They are a particularly attractive option in those cases where limbal-relaxing incisions are not powerful or predictable enough. Other toric lenses may correct astigmatism in addition to spherical refractive errors in phakic patients. RECENT FINDINGS: Toric lenses have continued to gain popularity with the US Food and Drugs Administration (FDA) approval of the Acrysof Toric intraocular lenses. This lens is designed to be implanted in patients undergoing cataract removal and who have significant preexisting corneal astigmatism. In the FDA clinical trial, study patients received one of the three cylindrical powers, and control patients received a standard monofocal intraocular lenses. The study found that the Acrysof Toric intraocular lenses provided excellent visual outcomes and exhibited excellent rotational stability. With the Acrysof Toric intraocular lenses, the average lens rotation was less than 4 degrees from the lens' initial placement at 6 months after surgery. SUMMARY: Toric intraocular lenses provide excellent vision for astigmatic cataract patients, and new designs are significantly improving visual acuity by minimizing the risk of rotation.

Astigmatism↗