PubMed HealthSearch

PubMed · 2270864

Cyanide detection using a substrate-regenerating, peroxidase-based biosensor.

Abstract

An enzyme-based, dual working electrode system is described for the sensing of cyanide. Horseradish peroxidase (HRP) is incorporated as the sensing element. A continuous monitoring of oxidative activity by the enzyme results through the generation and regeneration of substrates at the electrode surfaces. Thus, HRP is oxidized by hydrogen peroxide generated from dissolved oxygen, at the primary electrode, and then reduced through the secondary electrode by mediated electron transfer using ferrocene as a carrier. Ferrocene regeneration at this electrode is proportional to the intrinsic activity of HRP. The dynamics of the system are investigated by using a rotating ring-disk electrode. The enzyme is immobilized to provide better control over its catalytic activity and to increase the lifetime of the biosensor. Cyanide inhibition of current can be modeled by reversible binding kinetics. Detection of cyanide is possible in submicromolar (ppb) concentrations, with a half maximal response at 2 microM. The response time for detection of introduced cyanide is within 1 s. The sensor can be operated between 5 and 40 degrees C, and cyanide inhibition is unaffected by pH changes between 5 and 8. The sensor is reproducible for cyanide determination and is stable for over 6 months.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M H Smit, A E Cass. 1990-11-15. Cyanide detection using a substrate-regenerating, peroxidase-based biosensor.. https://doi.org/10.1021/ac00221a004

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

From host response to genomic targets: electrochemical biosensing of tuberculosis biomarkers.

Tuberculosis (TB) remains one of the leading causes of death from a single infectious agent worldwide, with timely diagnosis continuing to be a major challenge, particularly in resource-limited settings. Conventional TB diagnostic methods are limited by low sensitivity, long turnaround times, and an inability to reliably differentiate latent from active disease. Biomarker-based diagnostic strategies have therefore gained increasing attention as they offer the potential to improve early detection, disease differentiation, and treatment monitoring. Herein, we examine electrochemical biosensing strategies for TB diagnostics using a biomarker-class-driven framework, covering host-response biomarkers (IFN-γ and TNF-α), pathogen-derived antigens (ESAT6, CFP10, CFP10-ESAT6, MPT64, Ag85, HspX and LpqH), cell-wall signatures and whole-cell markers (LAM and whole cell Mtb), and genomic markers (Mtb DNA and IS6110). Through structured comparison of recognition elements, biointerface designs, signal amplification strategies, electrochemical techniques, matrices, and validation levels, this review identifies the most promising technical approaches for different TB biomarker classes. It further highlights key translational bottlenecks, including limited clinical validation, buffer-based testing, complex multistep amplification, redox-probe dependence, matrix fouling, and insufficient evidence of manufacturability. This review therefore provides practical guidance for developing electrochemical TB biosensors that are analytically sensitive, clinically relevant, and suitable for decentralized diagnostic applications.

Biosensing Techniques

Metal-organic frameworks nanozyme-integrated portable microneedle patch for visual bacterial monitoring in meat.

Foodborne microbial contamination is a major global health concern, with conventional methods often being time-consuming and complex. Herein, we developed a novel portable biosensor by integrating microneedle patch technology and a metal-organic framework (Fe/Cu-NBDC MOF) nanozyme, enabling rapid, on-site, visual detection of bacteria in meat. The sensing system works by encapsulating aptamer-functionalized MOF nanozymes within a hydrogel patch, where their catalytic sites are initially blocked by the aptamer. In the presence of Staphylococcus aureus (S. aureus) as the target, the specific aptamer's binding to bacteria exposes numerous catalytic sites, further activating the chromogenic reaction of the tetramethylbenzidine‑hydrogen peroxide (TMB-H₂O₂) system, enabling visual detection of S. aureus. The biosensor demonstrates a detection limit of 82 CFU/mL with excellent specificity to successfully apply to commercial mutton. By integrating sampling, enrichment, and visual detection into a single compact device, this platform offers a practical, efficient solution for rapid on-site screening of foodborne pathogens.

Biosensing Techniques