Personal computer interface and software for the ZONAX microscope attachment controller.

Abstract

We describe the hardware and software of a general-purpose interface that permits a personal computer (PC) running MS-DOS to control cytometric devices, e.g., a scanning stage, shutters, and focus motor attached to a microscope. This note explains how to use the interface to convert the ZONAX microscope attachment controller from 8080-based hardware control to PC-based control.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D R Rigney, J H Velyvis, J Y Wei. 1990. Personal computer interface and software for the ZONAX microscope attachment controller.. https://doi.org/10.1002/cyto.990110812

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Quality monitoring of soft-copy displays for medical radiography.

As presentation of medical radiographic images on soft-copy displays (cathode ray tubes) becomes increasingly prevalent in electronic radiography, methods of quality assurance must be developed to ensure that radiologists can effectively transfer film-based reading skills. Luminance measurements provide the basis for evaluating the state of soft-copy displays. An integrated approach has been implemented at Mallinckrodt Institute of Radiology (MIR, Washington University, St Louis, MO) that facilitates measurement of geographically distributed soft-copy displays with centralized data logging, performance tracking, and calibration. MIR's central radiology image manager exercises the display station that drives the monitor, harvests the measurement data, stores the results, and submits the resulting data for additional processing. The luminance measurements are collected by a small, portable, photometric instrument designed at MIR that includes a serial port that is accessed via local area terminal service supported by the radiology image manager. The design details of the photometric instrument and example luminance characteristics of several soft-copy displays used at MIR are presented in this report.

Computer Peripherals

Performance characteristics and image fidelity of gray-scale monitors.

Gray-scale monitors are an essential element of electronic radiology, and their ability to provide images that are perceived to be identical to those available on conventional or laser-printed film is crucial to success of electronic radiology. Image fidelity is measured in physical characteristics (luminance, dynamic range, distortion, resolution, and noise) and with psychophysical techniques, including receiver operator characteristics analysis with clinical images and testing with contrast-detail patterns to determine threshold contrast. Currently, laser-printed images facilitate greater information transfer than does a gray-scale monitor because of their higher absolute luminance (500 ft-L vs 60 ft-L), greater perceived dynamic range, and better spatial resolution. In the near future, the developments of gray-scale monitors with 150-200 ft-L luminance, a display standard based on just noticeable differences, and algorithms to improve similarities between gray-scale display images and laser-printed images will help increase the acceptability of monitors as a means to make primary diagnoses.

Computer Peripherals