PubMed HealthSearch

PubMed · 2299415

Surface microanalysis by reflection electron energy-loss spectroscopy.

Abstract

Several basic physical concepts of applying eq. Ik = I sigma Nxt to surface microanalysis by reflection electron energy-loss spectroscopy (REELS) are clarified. Here Ik and I are the integrated intensities of the core ionization edge and the low loss part, sigma is the scattering cross section of element x with atomic concentration Nx, and t is the specimen thickness. The reflected inelastic electrons are found to be distributed almost symmetrically around the Bragg spots and can be reasonably described by a Lorentzian function. EELS microanalysis can be performed by using the diffracted spots. The omega correction, arising from the angular contributions of the neighbouring spots into the spectrometer collecting aperture, is required to be considered.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Z L Wang. 1990. Surface microanalysis by reflection electron energy-loss spectroscopy.. https://doi.org/10.1002/jemt.1060140104

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Amorphisation of MgO single crystal specimens prepared by ion milling for transmission electron microscopy studies.

Single crystal MgO specimens having low load Vickers indentations were thinned in an ion milling machine employing a single ion gun, and their characteristics were investigated with optical microscopy and high voltage electron microscopy (HVEM). It was found that the state of cleanliness of the specimen chamber of the ion milling machine had a very marked influence on the quality of the thinned specimens. If the specimen chamber was not well cleaned before ion milling a fresh specimen, the latter tended to show amorphisation due to the deposition on the specimen of the debris left in the chamber from the previously ion-milled specimens. Such observations were made from MgO specimens ion milled in several different types of commercial ion milling machine employing a single gun. It is proposed that to obtain good-quality ion milled TEM specimens, it is important to clean the specimen chamber thoroughly prior to milling.

Magnesium Oxide

Direct-response ultraviolet thermoluminescent dosimeter.

An integrating solid-state dosimeter has been developed to detect ultraviolet radiation using the process of "direct" ultraviolet stimulation. This process yields a thermoluminescent signal after an exposure to ultraviolet radiation, without prior exposure to ionizing radiation. Magnesium oxide crystals were found to show a directly stimulated thermoluminescent glow peak at 145 degrees C which can be utilized as a linear, energy-independent ultraviolet dosimeter.

Magnesium Oxide