PubMed Health⌕ Search

PubMed · 2311113

Technical basis for magnetic resonance images.

Abstract

The spin-echo procedure is the basic technique in a magnetic resonance (MR) study (the magnetization vector is flipped by 90 degrees onto the ortogonal plane to the main magnetic field). Very soon after the MR procedure was developed, it was pointed out how important it is to achieve the needed contrast with shorter repetition times (TRs) to reduce the imaging time. Recently, fast imaging techniques have been introduced (partial flip angles, short TRs, and the lack of 180 degrees radiofrequency pulses to refocus the spins are their main characteristics; the spins are refocused by the application of a gradient reversal technique). These techniques are particularly needed in pediatric neuroradiology, where the examination time must be as short as possible. At present, partial flip-angle techniques are almost completely replacing the conventional spin-echo procedure, but the variations in flip angle could result in a change in contrast. For these reasons, conventional spin-echo techniques may still be useful in a routine MR study.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Passerini, L Strada, M Grisoli, M Sberna, M G Bruzzone. 1990. Technical basis for magnetic resonance images.. https://doi.org/10.1007/bf00262264

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A penalized likelihood approach to magnetic resonance image reconstruction.

Currently, images acquired via magnetic resonance imaging (MRI) and functional magnetic resonance imaging (fMRI) technology are reconstructed using the discrete inverse Fourier transform. While computationally convenient, this approach is not able to filter out noise. This is a serious limitation because the amount of noise in MRI and fMRI can be substantial. In this paper, we propose an alternative approach to reconstruction, based on penalized likelihood methodology. In particular, we focus on non-linear shrinkage estimators and show that this approach achieves a great reduction in integrated mean squared error (IMSE) of the estimated image with respect to the currently used estimator. This approach is extremely fast and easy to implement computationally. In addition, it can be combined with various alternative approaches to MR image reconstruction and can be easily adapted to other, non-MRI contexts, in which the observed data and the quantities of interest are related via a linear transform.

Brain Diseases↗