PubMed Health⌕ Search

PubMed · 2315242

Allergy testing by primary care physicians.

Abstract

Primary care physicians will treat allergy to some degree purely because of supply and demand. The effectiveness of treatment depends on their interest and involvement. A thorough history and physical examination are essential. Physicians should not depend on a remote, computerized plan for diagnosis and treatment. Various diagnostic tests are available, some appropriate to nearly all levels of interest. Primary care physicians must choose between referral, pharmacotherapy, or more extensive involvement in allergy care. Immunotherapy involves some risk and a better possibility of pure result, but it requires additional training. Food allergy cannot be diagnosed by in vitro tests. Elimination and challenge with subsequent long-term elimination of offending foods is the only practical course for primary care physicians.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H C King. 1990. Allergy testing by primary care physicians.. https://doi.org/10.1080/00325481.1990.11704601

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Recombinant truncated nucleocapsid protein as antigen in a novel immunoglobulin M capture enzyme-linked immunosorbent assay for diagnosis of severe acute respiratory syndrome coronavirus infection.

We report the development of an immunoglobulin M (IgM) antibody capture enzyme-linked immunosorbent assay (MAC-ELISA) for severe acute respiratory syndrome coronavirus (SARS-CoV) by using recombinant truncated SARS-CoV nucleocapsid protein as the antigen. The newly developed MAC-ELISA had a specificity and sensitivity of 100% as evaluated by using sera from healthy volunteers and patients with laboratory-confirmed SARS. Using serial serum samples collected from SARS patients, the times to seroconversion were determined by IgM antibody detection after SARS-CoV infection. The median time to seroconversion detection was 8 days (range, 5 to 17 days) after disease onset, and the seroconversion rates after the onset of illness were 33% by the first week, 97% by the second week, and 100% by the third week. Compared with the results of our previous report on the detection of IgG, the median seroconversion time by IgM detection was 3 days earlier and the seroconversion rate by the second week after the illness for IgM was significantly higher than by IgG assay. Our results indicating that the IgM response appears earlier than IgG after SARS-CoV infection in consistent with those for other pathogens. Our newly developed MAC-ELISA system offers a new alternative for the confirmation of SARS-CoV infection.

Enzyme-Linked Immunosorbent Assay↗

Perfusion with lipopolysaccharide differently affects the secretion of tumor necrosis factor-alpha and interleukin-6 by term and preterm human placenta.

This study has compared the functional capacity of term and preterm placentas in terms of production of pro-inflammatory cytokines in a perfusion system reflecting their ability to react to inflammatory agents, such as lipopolysaccharide (LPS), mimicking the situation of chorioamnionitis. We have demonstrated that term placentas secrete higher levels of tumor necrosis factor (TNF)-alpha compared with preterm placentas. Moreover, TNF-alpha secretion was significantly higher after exposure to LPS in the maternal and fetal sides of term placentas. In contrast, in preterm placentas, only the fetal side responded with a significant increase in secretion of TNF-alpha after exposure to LPS. The maternal side of term placentas secreted significantly higher amounts of interleukin (IL)-6 compared with preterm placentas. Exposure to LPS significantly decreased IL-6 secretion from the maternal side in both term and preterm placentas. Moreover, the fetal side of term placentas secreted significantly lower amounts of IL-6 compared with preterm placentas. In summary, this study has indicated that term and preterm placental tissues have a differing responsiveness to LPS stimulation, with term placentas disposed to a higher TNF-alpha:IL-6 ratio. Release of cytokines into fetal circulation is less than into the maternal side. However, TNF-alpha is released into fetal circulation after LPS stimulation and this may be relevant to the etiology of chorioamnionitis.

Enzyme-Linked Immunosorbent Assay↗