PubMed HealthSearch

PubMed · 2334772

A software package for event related potential experiments.

Abstract

All too frequently, researchers find that experimental designs are dictated by procedures implemented by the available equipment rather than by the questions to be answered. Event related potential experiments are limited by equipment which restricts the type and number of stimuli which can be presented and the length, number, and type of averages which can be computed. A software package was developed for event related potential experiments which provides a high degree of flexibility in designing the stimulus presentation protocol and the averages which can be computed. The package includes a set of user friendly programs for constructing complicated stimulus presentation sequences. In order not to restrict the researcher to a set of predetermined averages computed at the time the experiment is conducted, the EEG data is digitized and stored continuously without regard to times of stimulus presentation. Averages are computed from the continuous EEG data by a separate averaging program which takes as input a table of starting times of the segments to be averaged. The software package is currently in use at Dr. Rohrbaugh's laboratory for a series of complicated event related potential experiments.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J L Varner, J W Rohrbaugh. 1990. A software package for event related potential experiments.. https://pubmed.ncbi.nlm.nih.gov/2334772/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Quantification of inter- and intra-nuclear variation of fluorescence in situ hybridization signals.

This study aims at the quantification of specific DNA sequences by using fluorescence in situ hybridization (ISH) and digital imaging microscopy. The cytochemical and cytometric aspects of a quantitative ISH procedure were investigated, using human peripheral blood lymphocyte interphase nuclei and probes detecting high copy number target sequences as a model system. These chromosome-specific probes were labeled with biotin, digoxigenin, or fluorescein. Quantification of the fluorescence ISH signals was performed using an epifluorescence microscope equipped with a multi-wavelength illuminator, and a cooled charge coupled device (CCD) camera. Specific image analysis programs were developed for the segmentation and analysis of the images provided by ISH. The fluorescence intensity distributions of the ISH spots showed large internuclear variation (CVs up to 65%) for the probes used. The variation in intensity was found to be independent of the probe, the type of labeling, and the type of immunocytochemical detection used. Variation in intensity was not caused primarily by the immunocytochemical detection method, since directly fluorescein-labeled probes showed similar internuclear variation. Furthermore, it was found that different white blood cell types, which harbor different degrees of compactness of the nuclear chromatin, showed the same variation. The intra-nuclear variation in intensity of the ISH spots on the two chromosome homologs within one nucleus was significantly smaller (approximately 20%) than the inter-nuclear variation, probably due to more constant local hybridization conditions. Due to the relatively small intranuclear variation, copy number polymorphisms of the satellite DNA sequence on chromosome 1 could readily be quantified.(ABSTRACT TRUNCATED AT 250 WORDS)

Analog-Digital Conversion

Fluorescence ratio measurements of double-labeled probes for multiple in situ hybridization by digital imaging microscopy.

To expand the multiplicity of the in situ hybridization (ISH) procedure, which is presently limited by the number of fluorochromes spectrally separable in the microscope, a digital fluorescence ratio method is proposed. For this purpose, chromosome-specific repetitive probes were double-labeled with two haptens and hybridized to interphase nuclei of human peripheral blood lymphocytes. The haptens were immunocytochemically detected with specific antibodies conjugated with the fluorochromes FITC or TRITC. The FITC and TRITC fluorescence intensities of spots obtained with different double-haptenized probes were measured, and the fluorescence ratio was calculated for each ISH spot. Combinations of different haptens, such as biotin, digoxigenin, fluorescein, sulfonate, acetyl amino fluorene (AAF), and mercury (Hg) were used. The fluorescence intensity ratio (FITC/TRITC) of the ISH spots was fairly constant for all combinations used, with coefficients of variation between 10 and 30%. To study the feasibility of a probe identification procedure on the basis of probe hapten ratios, one probe was double-labeled with different ratios, by varying the relative concentrations of the modified nucleotides (biotin-11-dUTP and digoxigenin-11-dUTP) in the nick-translation reaction. Measurement of the FITC and TRITC intensities of the ISH spots showed that the concentration of modified nucleotides used in the labeling procedures was reflected in the mean fluorescence intensity of the ISH spots. Furthermore, the ratio distributions showed little overlap due to the relatively small coefficients of variation. The results indicate that a multiple ISH procedure based on fluorescence ratio imaging of double-labeled probes is feasible.

Analog-Digital Conversion