A method for counting leukocytes in filtered components.

Abstract

Leukocyte-depleted components are being used more frequently. Quantitation of residual WRCs is needed for quality control and for establishing the critical level required to prevent alloimmunization. Electronic counting is not accurate at WBC levels below 100/microL (1) and previously proposed techniques are either tedious or require sophisticated equipment. We describe a simple hemacytometer procedure using Türks solution that gives 87-93% recovery at WBC levels below 40/microL.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T J Greenwalt, C M Allen. 1990. A method for counting leukocytes in filtered components.. https://doi.org/10.1046/j.1537-2995.1990.30490273449.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Use of a fluorescence plate reader for measuring kinetic parameters with inner filter effect correction.

A general method is presented here for the determination of the Km, kcat, and kcat/Km of fluorescence resonance energy transfer (FRET) substrates using a fluorescence plate reader. A simple empirical method for correcting for the inner filter effect is shown to enable accurate and undistorted measurements of these very important kinetic parameters. Inner filter effect corrected rates of hydrolysis of a FRET peptide substrate by hepatitis C virus (HCV) NS3 protease at various substrate concentrations enabled measurement of a Km value of 4.4 +/- 0.3 microM and kcat/Km value of 96,500 +/- 5800 M-1 s-1. These values are very close to the HPLC-determined Km value of 4.6 +/- 0.7 microM and kcat/Km value of 92,600 +/- 14,000 M-1 s-1. We demonstrate that the inner filter effect correction of microtiter plate reader velocities enables rapid measurement of Ki and Ki' values and kinetic inhibition mechanisms for HCV NS3 protease inhibitors.

Filtration

Analog filtering of large solvent signals for improved dynamic range in high-resolution NMR.

The large solvent signal from samples in H2O solvent still challenges the dynamic range capability of any spectrometer. The solvent signal can be largely removed with a pair of simple resistor-capacitor (RC) high-pass filters when the solvent frequency is set at center band (zero frequency) using quadrature detection, with RC approximately 0.5 ms. However, an approximately 0.5-ms transient remains at initial time, which we reduce fourfold for a short time only, just before the A/D converter, by means of a variable-gain amplifier, and later restore with software. This modification can result in a nearly fourfold increase in dynamic range. When we converted to a frequency-shifted mode (A. G. Redfield and S. D. Kunz, 1994, J. Magn. Reson. A 108, 234-237) we replaced the RC high-pass filter with a quadrature feedback notch filter tuned to the solvent frequency (5.06 kHz). This filter is an example of a class of two-input/two-output filters which maintain the spectral integrity (image-free character) of quadrature signals. Digital filters of the same type are also considered briefly. We discuss the implications of these ideas for spectrometer input design, including schemes for elimination of radiation damping, and effects of probe bandwidth on extreme oversampling.

Filtration