PubMed Health⌕ Search

PubMed · 2388110

Method for setting total graft force and load sharing in augmented ACL grafts.

Abstract

The objective of this study was to develop a method for obtaining a controllable and reproducible immediate postoperative mechanical state in a knee with an anterior cruciate ligament (ACL) reconstruction. This method, called the force-setting technique, was demonstrated using a composite graft consisting of the middle third of the patellar tendon with bone blocks (PT) and the ligament augmentation device (LAD). The total graft force was set to match the force in the intact ACL at 30 degrees flexion with the knee under the same standardized external load, while at the same time the load sharing between the biologic and augmentation components was controlled. The total graft force was set to match the ACL force three separate times in each knee, with ratios of load sharing set at the following levels: 50% PT-50% LAD, 25% PT-75% LAD, and 75% PT-25% LAD. ACL, PT, LAD, and collateral forces were measured using buckle transducers, and three-dimensional knee motion was measured using an instrumented spatial linkage as 90 N anteriorly directed tibial loads were applied to eight specimens at 0 degree, 30 degrees, 60 degrees, and 90 degrees flexion with an intact ACL, an excised ACL, and the three load-sharing reconstruction states. The total graft force could be consistently set to within an average of 2% of the intact ACL force at 30 degrees flexion, and load sharing between the graft segments could be set to within an average of 5.1% of the desired ratio at 30 degrees.(ABSTRACT TRUNCATED AT 250 WORDS)

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W D Lew, L Engebretsen, J L Lewis, R E Hunter, C Kowalczyk. 1990. Method for setting total graft force and load sharing in augmented ACL grafts.. https://doi.org/10.1002/jor.1100080512

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A population-based study of cancer incidence in solid organ transplants from donors at various risk of neoplasia.

A population-based cohort study of recipients of organs from donors with a recognized history or active cancer has been conducted by linking the Italian National Registry of Transplanted Patients and the National Registry of Donors with Neoplasia Risk. Between 2002 and 2004, 8,198 solid organ transplants have been performed in Italy, 108 of them with organs from 59 cadaveric donors with various risk of neoplasia. There were two reported cases of nonmelanoma skin cancer during the follow up of the transplanted patients, which lasted 27.6+/-11.3 months (234 patient-years). In our study, recipients of organs from donors with various degree of neoplasia risk are exposed to a low risk of cancer transmission.

Cadaver↗

[Primary stability of the capsule-labrum complex after reconstruction with the Mitek Bioknotless anchor system in human cadaver models].

BACKGROUND: This study examines the postoperative stability of the Mitek Bioknotless anchor system with biomechanical draw-out pulling in human cadaver shoulders. METHOD: With simulation of anterior shoulder dislocation a test group (n=10, Ø 45 years) was tested against a native group (n=8, Ø 47 years). All shoulders were dissected up to the passive stabilizers. In the test group an artificial Bankart lesion was created and repaired with three Mitek Bioknotless anchors. The humeri of both groups were fixed in 60 degrees glenohumeral abduction and 90 degrees external rotation and then dislocated in a ventral direction. For evaluation purposes the ultimate draw-out strength, mode of failure, translation of humeral head, capsular slope, and bone density in the test group were measured. RESULTS: In the test group the ultimate strength was a median of 937 N (min. 554 N, max. 1,294 N) with 28 bony anchor dislocations, 1 suture rupture, and 1 capsular rupture, and in the native group with 6 Bankart and 2 HAGL lesions it was 1,214 N (708 N, 1,471 N). The bone density showed a positive correlation to the draw-out strength regarding cortical density and total density. CONCLUSION: Regarding the high draw-out strength the Mitek Bioknotless anchor system provides enough stability for early functional treatment.

Cadaver↗