Real-time reconstruction of evoked potentials using a new two-dimensional filter method.

Abstract

Standard techniques for evoked potential recording extract a stimulus-locked event from accompanying noise by averaging a large number of sequentially obtained responses. This approach is valid only to the extent that the nervous system's electrical response to successive stimuli is identical. The technique is suboptimal for recording unstable evoked potentials which vary with the subject's state and attention. Similarly, standard methods are suboptimal for efficiently analyzing rapid changes such as may be seen in the operating room. We developed an evoked potential recording method that reconstructs the individual evoked responses (or small subaverages of evoked potentials) to a series of stimuli. First, the raw data from an entire series of one to several hundred responses are recorded digitally. Using a frequency domain two-dimensional filter, the data are then filtered twice, once along the data sequence axis for each trial, and again along the cross-trial sequence axis for comparable frequency coefficients in sequential trials. The reconstructed filtered evoked potentials are plotted, with successive responses stacked for easy tracking of component changes.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J A Sgro, R G Emerson, T A Pedley. 1985. Real-time reconstruction of evoked potentials using a new two-dimensional filter method.. https://doi.org/10.1016/0168-5597(85)90046-2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A Kalman filter based methodology for EEG spike enhancement.

In this work, we present a methodology for spike enhancement in electroencephalographic (EEG) recordings. Our approach takes advantage of the non-stationarity nature of the EEG signal using a time-varying autoregressive model. The time-varying coefficients of autoregressive model are estimated using the Kalman filter. The results show considerable improvement in signal-to-noise ratio and significant reduction of the number of false positives.

Electroencephalography↗

Visual evoked potential in the newborn: does it have predictive value?

We reviewed studies on the predictive value of visual evoked potentials (VEPs) in the newborn. VEPs demonstrated a good correlation with neurodevelopmental outcome in full-term infants with birth asphyxia. However, their prognostic value in preterm infants is controversial. In preterm infants, most studies showed high specificities for neurodevelopmental outcome, but some studies demonstrated lower sensitivities.