On the interaction of the first complement component C1 and its subunit C1q with solid-phase IgM immune complexes.

Abstract

The interaction of C1 and C1q with solid-phase anti-dextran MOPC-104E IgM was studied. An enzyme-linked immunosorbent assay (ELISA) was used to detect bound C1q. The results revealed that immobilized IgM is converted to the functionally active 'staple' conformation by the specific polyvalent ligand dextran (B 1355/S). C1q is fixed to IgM dependent on the antigen concentration, and its binding might be explained by assuming a functional binding constant (K) of approximately 10(9) M-1. Molecules bound with a K in the range of 10(7) M-1 cannot be detected by this ELISA procedure. The fixation of C1q saturated with an excess of the C1r2S2-tetramer differs from that of free C1q. C1q incorporated in the C1 complex rapidly dissociates independently of the antigen concentration. Since the complement binding sites are located at definite positions on the IgM molecule because of its pentameric structure, it is suggested that the distinguishable association properties of C1 and C1q are brought about from the altered flexibility of the C1q molecule complexed with C1r2S2.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E M Weiner. 1988. On the interaction of the first complement component C1 and its subunit C1q with solid-phase IgM immune complexes.. https://doi.org/10.1111/j.1365-3083.1988.tb01471.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Immune complexes suppress IFN-gamma signaling by activation of the FcgammaRI pathway.

Antigen-driven immune responses are modulated by immune complexes (ICs), in part through their ability to inhibit IFN-gamma-dependent MHC Class II expression. We have demonstrated previously that ICs dramatically inhibit IFN-gamma-induced activation of human monocytes through the suppression of the JAK/STAT signaling pathway. In the current study, we further explore the mechanisms by which ICs regulate IFN-gamma activation of human monocytes. Consistent with previous studies in monocytes pretreated with ICs, there was a reduction in steady-state levels of RNA by real-time RT-PCR of the IFN-inducible protein 10 gene as well as the FcgammaRI gene. Pull-down assays confirm that IC pretreatment inhibits IFN-gamma-induced STAT1 phosphorylation without affecting the ability of STAT1 to bind to the STAT1-binding domain of the IFN-gamma receptor. In addition, the inhibitory function of ICs was reduced when cells from the FcR common gamma-chain knockout mice were used, supporting the role of the FcgammaRI in this inhibitory pathway. It is unexpected that ICs also require the phosphatase Src homology-2-containing tyrosine phosphatase 1 (SHP-1) to inhibit IFN-gamma induction, as demonstrated by studies with cells from the SHP-1 knockout (motheaten) mice. These data suggest a mechanism of IC-mediated inhibition of IFN-gamma signaling, which requires the ITAM-containing FcgammaRI, as well as the ITIM-dependent phosphatase SHP-1, ultimately resulting in the suppression of STAT1 phosphorylation.

Antigen-Antibody Complex↗

Immuno-mass spectrometry assay of EPI-HNE4, a recombinant protein inhibitor of human elastase.

In order to increase the sensitivity of liquid chromatography/mass spectrometry (LC/MS) assays of recombinant proteins for pharmacokinetics studies, we have developed an immuno-mass spectrometry assay for EPI-hNE4, a 6237 Da protein currently developed for respiratory distress syndromes. After immunocapture of the analyte in human plasma with magnetic beads coated with anti-EPI-hNE4 antibodies, the intact protein was eluted and separated in reversed-phase LC and then analysed by tandem mass spectrometry (MS/MS) in selected reaction monitoring (SRM) mode. The problem of analytical interference due to endogenous binding antibodies was addressed by successive steps of acidification and neutralisation before immunocapture. Furthermore, potential variations in the recovery of analyte during sample extraction were compensated for by addition of an internal standard recognised by the antibodies. The precision of the assay remained therefore below 15%. A significant increase in assay sensitivity was achieved since the extraction step allowed sample concentration and removal of matrix components interfering with the electrospray ionisation process. Using 0.4 mL of plasma, a limit of quantification at 0.5 ng/mL (80 pM) was reached, which represents a 10-fold improvement in sensitivity over our previous work using sample precipitation. This technique was able to monitor EPI-hNE4 kinetics in the plasma of human subjects for 36 h after an intravenous administration of 0.125 mg/kg.

Antigen-Antibody Complex↗

Antibody arrays for quantitative immunophenotyping.

Detection of multiple surface antigens expressed on living cell is an important step for cell processing and clinical diagnosis. Here we describe the preparation of antibody arrays that allow parallel detection of multiple surface antigens through affinity binding of living cells. An antibody array was fabricated by photo-assisted patterning of an alkanethiol monolayer formed on a gold-coated glass plate and subsequent immobilization of antibodies specific for cell surface antigens in an array format. We demonstrate here that rapid phenotyping can be performed on the array for both adhesion-dependent and non-dependent cells by direct cell binding assays. The density of bound cells on each antibody spot was in accordance with their contents in an original suspension. This result suggests the feasibility of the array-based method for quantitative assessment of multiple antigen expression. These findings will serve to extend the range of fundamental and clinical applications of antibody arrays.

Antigen-Antibody Complex↗