PubMed Health⌕ Search

PubMed · 2472629

Low dose dextran 40 in reconstructive hip surgery patients.

Abstract

Preoperative and postoperative bilateral lower extremity venography was used to evaluate the efficacy of low dose dextran 40 in prophylaxis of deep venous thrombosis in reconstructive hip surgery patients. Patients were given dextran 40 at 50 cc/hr, with 250 cc given perioperatively and 500 cc given on postoperative days two and four. Five of 227 patients had positive venograms preoperatively. Of these 227 patients, 179 met protocol requirements and had venography postoperatively. Venous thrombosis occurred in 33 (18%) of those studied postoperatively. Of these, 11 were calf clots without extension to the popliteal region. Therefore, there were 22 patients (12%) with femoral or popliteal involvement overall. There were two deaths, neither of which was secondary to pulmonary embolus or a complication of dextran. There were two wound complications. These results suggest that low dose dextran 40 administered as indicated is a safe and efficacious means of deep venous thrombosis prophylaxis in reconstructive hip surgery patients.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T S Roberts, C L Nelson, C L Barnes, D W Boone, E J Ferris, J L Holder. 1989. Low dose dextran 40 in reconstructive hip surgery patients.. https://doi.org/10.3928/0147-7447-19890601-05

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Dry reagent dipstick test combined with 23S rRNA PCR for molecular diagnosis of bacterial infection in arthroplasty.

Periprosthetic joint infections present a challenging problem in orthopaedics. Conventional methods for detection of arthroplasty infections rely on bacterial culture of synovial fluid aspirates. During recent years, however, molecular tests that are based on DNA amplification by the polymerase chain reaction (PCR), followed by electrophoretic analysis of the products, have been introduced. We report a simple and inexpensive assay that allows visual detection and confirmation of the PCR-amplified sequences by hybridization within minutes. The assay is performed in a dry reagent dipstick format (strip) and does not require special instrumentation. Universal primers are used for PCR of the 23S ribosomal RNA (rRNA) gene. The biotinylated amplification product is hybridized with dA-tailed probes that are specific for six pathogens commonly involved in periprosthetic joint infections. The mixture is applied to the strip, which is then immersed in the appropriate buffer. The buffer migrates along the strip by capillary action and rehydrates gold nanoparticles with oligo(dT) strands attached to their surface. The nanoparticles bind to the target DNA through hybridization, and the hybrids are captured by immobilized streptavidin at the test zone of the strip, producing a characteristic red line. Unbound nanoparticles are captured by immobilized oligo(dT) strands at the control zone of the strip, generating a second line. The dipstick test was applied to the detection of Escherichia coli, Staphylococcus aureus, Staphylococcus epidermidis, Streptococcus pneumoniae, Enterococcus faesium, and Haemophilus influenza. Twelve samples of synovial fluids from patients were analyzed for the detection and identification of the infection caused by the six pathogens. The results were compared with bacterial cultures.

Arthroplasty↗