PubMed HealthSearch

PubMed · 2525721

[Left ventricular function in obstructive chronic bronchopneumopathy].

Abstract

Left ventricular (LV) function was studied, using echocardiography, radionuclide angiography and right catheterization, in 20 patients (mean age 60.9 +/- 1.5 years) with severe stable chronic obstructive pulmonary disease (COPD) and without known heart disease. The diagnosis of LV failure, suspected on clinical grounds in 8 of these patients, was confirmed by raised pulmonary capillary wedge pressure (PCWP) in only one patient. Nineteen subjects had normal PCWP and LV ejection fraction (LVEF) values, radionuclide LVEF and end diastolic LV dimension being the most powerful discriminators between the single abnormal patient and the others. Echocardiograms of sufficient quality were obtained in 11 out of the 19 normal patients and constantly showed LV dimensions in the lowest part of the normal range. The stroke volume index (SVI) - cardiac output being measured by thermodilution - was found to be decreased in 9 of 14 patients with normal LVEF values. We conclude that in patients with severe COPD (1) LV failure is quite unfrequent and the empirical use of digitalis should not be recommended, (2) radionuclide angiography is the most useful procedure for routine evaluation of LV function and (3) a decreased SVI is frequently found in patients with a small LV cavity and a normal LVEF, suggesting some degree of diastolic dysfunction of the left ventricle.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Noseda, T Verbeet, M Verhas, P De Coodt, M Telerman, J Schmerber. 1989-05-13. [Left ventricular function in obstructive chronic bronchopneumopathy].. https://pubmed.ncbi.nlm.nih.gov/2525721/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Determination of circulating blood volume by measurement of indocyanine green dye in hemolysate: a preliminary study.

In 8 emergency care patients blood volume was determined using Cr5I labelled erythrocytes and indocyanine green (ICG). Prior to measurement of ICG in blood with a spectrophotometer, the blood was hemolyzed with Triton-X. A close correlation of r = 0.97 between the Cr51 and the ICGTR-X estimates was found; the ICGTR-X volume was about 3% lower than the Cr51 volume. In five additional in vitro experiments the ICGTR-X method was found to reflect real volumes with an insignificant error of less than 1%. Blood volume determination with ICGTR-X cannot be applied in cases of circulatory failure. ICG should be administered in a dose of 0.5 mg/kg of body weight. For calibration purposes, a two point calibration curve (point 1: point of intersection of x and y axis; point 2: 5 mg ICG/1 of blood) is sufficient. From these preliminary experiments it is concluded that the ICGTR-X method is a rapid and simple technique of blood volume determination with multiple reproducibility which can be carried out in any clinical laboratory.

Blood Volume Determination

[The determination of the volume of circulating plasma using the indicator T-1824].

A method for measuring circulating plasma volume (CPV) by diluting T-1824 indicator is described, making allowance for the exponential pattern of labeled serum albumin elimination from the vascular bed. The method consists in double collection of blood samples after intravenous injection of the indicator, computation of the constant of its extravasation rate, and extrapolation to the zero time. Analysis of the results obtained by this method and CPV values derived from the hematocrit and circulating blood volume--(CBV) estimated with the help of Albert table (1971), as well as with CPV value derived from the hematocrit and CBV measured by impedance method in 22 patients with slight uncomplicated ventral and diaphragmal hernias has demonstrated high linear correlation coefficients, +0.77 and +0.78 (p less than 0.01), respectively.

Blood Volume Determination