PubMed Health⌕ Search

PubMed · 2604967

Amalgam restoration completion. Objectives, methods and armamentarium.

Abstract

The success of an amalgam restoration is multifactorial. Attention must be paid to the manipulation and condensation of the alloy, the final contouring, and the finishing procedures. A discussion of current amalgam alloy, including the goals and sequence of the restorative procedure, are presented with emphasis on the instruments and methods.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Ben-Amar, L Serebro, C Gorfil. 1989. Amalgam restoration completion. Objectives, methods and armamentarium.. https://pubmed.ncbi.nlm.nih.gov/2604967/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Failure mode of dental restorative materials under Hertzian indentation.

OBJECTIVE: To explore the application of Hertzian indentation testing to amalgam and GIC; study the failure behavior of the bi-layer structure of each material on a relatively soft substrate; and investigate the effect of thickness. METHODS: Amalgam (Lojic+, SDI, Bayswater, Australia) and ceramic-reinforced GIC (Advanced Healthcare, Tonbridge, UK) discs, 10 mm diameter, thicknesses ranging from 0.4 to 8.0 mm, were tested resting freely on a substrate (30% glass fibre-reinforced polyamide; E=10GPa, 10 mm diameter and 5 mm thick). Increasing load was applied to the center of the disc by a 20 mm-diameter hard steel ball until fracture occurred. Acoustic emission sensing was used as a supplemental method for crack detection. The load at the first crack was recorded. Fracture surfaces were observed under SEM to identify the crack initiation site and the failure mode. RESULTS: The main failure mode of both materials shifted from bottom-initiated radial cracking to near-contact cone cracking or subsurface plastic deformation as the thickness was increased. There was a wide thickness range for the transition of the failure mode for amalgam. Failure load was proportional to the square of thickness for amalgam, except for deviations at small and very large thickness; for the GIC, it was proportional to the thickness to the power approximately 1.6, except for thin layers. SIGNIFICANCE: The Hertzian indentation test can be applied to investigate the failure behavior of amalgam and GIC in addition to ceramics, for which purpose it may have value as a routine test. Failure mode changed with specimen thickness. The importance of considering both failure mode and failure load or strength is emphasized.

Dental Amalgam↗