Incorrect least-squares regression coefficients in method-comparison analysis.

Abstract

The least-squares method is frequently used to calculate the slope and intercept of the best line through a set of data points. However, least-squares regression slopes and intercepts may be incorrect if the underlying assumptions of the least-squares model are not met. Two factors in particular that may result in incorrect least-squares regression coefficients are: (a) imprecision in the measurement of the independent (x-axis) variable and (b) inclusion of outliers in the data analysis. We compared the methods of Deming, Mandel, and Bartlett in estimating the known slope of a regression line when the independent variable is measured with imprecision, and found the method of Deming to be the most useful. Significant error in the least-squares slope estimation occurs when the ratio of the standard deviation of measurement of a single x value to the standard deviation of the x-data set exceeds 0.2. Errors in the least-squares coefficients attributable to outliers can be avoided by eliminating data points whose vertical distance from the regression line exceed four times the standard error the estimate.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P J Cornbleet, N Gochman. 1979. Incorrect least-squares regression coefficients in method-comparison analysis.. https://pubmed.ncbi.nlm.nih.gov/262186/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

An evaluation of the Ramco kit for serum ferritin assay.

The determination of serum ferritin levels may be of diagnostic importance in medicine. To establish whether values obtained using a commercially available kit (Ramco) were adequate for this purpose, a comparison was undertaken using a two-site immunoradiometric assay that had been developed and standardized in our laboratories. Over the range 6 micrograms/l to greater than 2 000 micrograms/l there was a correlation coefficient between the two methods of 0,8284 (P less than 0.001). It is concluded that the Ramco kit is suitable for use in clinical practice.

Blood Chemical Analysis

Use of microbore columns for the separation of substances of biological origin.

A gradient system for use with microbore columns is described and the repeatability of the system determined. A simple sampling device for use with aqueous biological samples is described, and the advantages of the high mass sensitivity of microbore columns for the analysis of such samples are discussed. The sensitivity of the system is demonstrated by the determination of acetophenone in water at a level of one part per billion. The use of the apparatus for the separation of low-molecular-weight, non-ionic compounds contained in blood is also demonstrated. It is shown that excellent separations of such components can be obtained from as little as 400 microliter of serum.

Blood Chemical Analysis