Abstract

Microprocessors have enabled new techniques to be applied to the design of tonometers. Three new microprocessor controlled tonometers, one operating to the principle of Mackay-Marg (Tono-Pen) and two non-contact airstream tonometers (Pulsair and CT-10) have been examined using as a reference Goldmann and the Hand Held Applanation Tonometers (Draeger-HAT) which used the Goldmann applanation principle. The non-contact tonometers produce a conically formed airstream with top speeds of 90 m/s (CT-10) and 70 m/s (Pulsair) which at the moment of pressure measurement applanates the cornea exactly with a diameter of 4 mm. The readings of the microprocessor controlled tonometers correlate well with the readings of HAT (Tono-Pen r = 0.8414 and s = 3.783, CT-10 r = 0.8606 and s = 4.5477, Pulsair r = 0.8968 and s = 3.2641, where r is the correlation coefficient and s is the standard deviation in mmHg). Repeated measurements with one tonometer give the following standard deviations (HAT 1.6617, Tono-Pen 3.4969, CT-10 2.9179, Pulsair 2.9434). Although the three new instruments are able to measure the intraocular pressure in a wide range they do not work with the same precision as the classical applanation tonometer.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Draeger, E Rumberger, J Dauper, C Deutsch. 1989. Microprocessor controlled tonometry.. https://doi.org/10.1038/eye.1989.114

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Transjugular intrahepatic portosystemic stent shunt (TIPSS) with use of Rösch-Uchida transjugular liver access set--evaluation by CT and its clinical application].

Appropriateness of the Rösch-Uchida transjugular liver access set designed for TIPSS procedure was confirmed, especially about the catheter angle and effective length of the 20 G puncture needle, by CT analysis on three dimensional vascular anatomy of the liver. Clinically, TIPSS using the set was successfully made for two patients, connecting superior right hepatic vein with right portal vein in one patient and middle hepatic vein with left portal vein in another patient with hypoplastic right portal vein. Prior to TIPSS procedure, verification of vascular anatomy on CT images is the key to success of TIPSS in safe.

Evaluation Studies as Topic

[Testing an ultrasonic scanner for determination of urinary bladder volume].

Bladderscan BVI 2000 is a portable ultrasound scanner, specially constructed for determination of bladder volume. We have tested this scanner for accuracy, systematic errors and the training required to use it. The bladder volumes measured by ultrasound scanning were compared with the true volumes. Fifty-six measurements were made. We found the accuracy of BVI 2000 sufficient to determine bladder volumes as either small or large. We found no systematic errors. No special training is required to use the scanner. The device is thus useful in most clinical situations when greater accuracy than indicated here is not necessary.

Evaluation Studies as Topic