Abstract

The partial thromboplastin time (PTT) test is widely used as a screening test for the detection of hemophilia. It is also used to monitor patients on heparin anticoagulation. These proposed guidelines for the performance of this test, including comparable reference ranges, precision and sensitivity requirements are felt to be reasonable and attainable. Whether further progress will occur depends upon a perceived need by laboratorians, instrument and reagent manufacturers and government regulators that standardization of the PTT is desirable.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J A Koepke. Performance guidelines for the partial thromboplastin time test.. https://doi.org/10.1007/bf02871826

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A reconstituted dilute blood clot lysis assay for the medium throughput screening of thrombolytic compounds.

Antithrombotic and clotting factors have long been targets for drug discovery, necessitating the development of blood assays to determine the efficacy of lead compounds prior to animal testing. We have developed a reconstituted blood clot lysis assay which eliminates the need for on-site donors. The assay uses whole blood stored at 4 degrees C obtained from a local blood bank, diluted 1:10 in phosphate buffer. This blood was supplemented with 125I-labeled fibrinogen and the release of radioactive fibrinopeptides from formed clots was measured. The whole blood used in this assay, which had been stored at 4 degrees C for several days, no longer formed solid or retracting clots. Thus, platelets 5-7 days ex vivo (165 x 10(6) platelets) were added to the whole blood in the presence of thrombin (0.80 IU/ml) to form clots. Solid clots formed within 2 min of thrombin addition and began retracting shortly thereafter. In the absence of any thrombolytic agent, clots fully retracted within 2.5 h and remained stable. Thrombin-stimulated clot formation was completely inhibited by heparin. Clots could be lysed in a dose-dependent fashion in the presence of tissue-type plasminogen activator. Clot lysis could be completely inhibited in a dose-dependent fashion with plasminogen activator inhibitor type 1. To demonstrate the utility of this assay as a screen for thrombolytic agents, a 14-amino-acid PAI-1-inhibitory peptide relieved the PAI-1 effect on tPA in a dose-dependent fashion. These data describe an assay for the screening of potential pro-fibrinolytic agents that target PAI-1 inhibition in a human plasma-based system that is versatile, cost-effective, and physiologically relevant and does not rely on the availability of on-site blood donors.

Blood Coagulation Tests

[Rational hemostatic screening].

BACKGROUND: In order to exclude hemorrhagic diathesis, e.g. before diagnostic measures carrying the risk of bleeding or in preoperative situations, a graded screening is advisable. PROCEDURE: During the first stage, besides the anamnesis, clinical examination and classification of relevant concomitant diseases (e.g. liver cirrhosis or renal insufficiency), basic laboratory examinations such as prothrombin time, activated partial thromboplastin time (aPTT) and platelet count must be carried out. Should all these measures produce no noteworthy results, no further examinations are necessary. However, in the case of test results within normal limits accompanied by an unsatisfactory anamnesis and/or conspicuous clinical findings, the second stage should include examination of bleeding time according to Mielke to exclude a relevant platelet dysfunction. Should this be inconspicuous a third stage should follow in which successive implementation is made of fibrinogen according to Clauss, the Rumpel-Leede test (to exclude heightened capillary fragility), factor XIII and alpha 2-antiplasmin. The methodical snares of the parameters mentioned will be explained in full.

Blood Coagulation Tests

Continuous infusion of FVIII and FIX concentrates: in vitro analysis of clinically relevant parameters.

A high purity factor VIII/von Willebrand Factor (FVIII/vWF) concentrate (IMMUNATE [STIM plus]) (n = 6 batches), and a high purity factor IX (FIX) concentrate (IMMUNINE [STIM plus]) (n = 7 batches), were assessed in vitro for their applicability to continuous infusion. Parameters pertinent to continuous infusion were investigated and included stability, sterility and, in the case of FIX, the generation of potentially thrombogenic components. Four stationary or transportable mini infusion pumps, equipped with polyethylene, polypropylene or polyvinylchloride plastic components were used. The concentrates were reconstituted without extra filling volume and perfused at 12.5 mL h-1 and 1 mL h-1; sampling was carried out at the start of the experiment and for up to 48 h. The FVIII procoagulant activity (FVIII:C) was assayed by amidolytic, 1-stage and 2-stage assays; vWF was examined for ristocetin cofactor activity, antigen and multimers. The FIX coagulation activity (FIX:C) was determined by a 1-stage coagulation assay; thrombogenicity potential was assessed in vivo (Wessler stasis model in rabbits) and in vitro (FIXa and nonactivated thromboplastin time). Reconstituted concentrate incubated under the same conditions served as a control. Both concentrates remained sterile throughout the testing period. The perfused and control samples remained stable, retaining over 95% of activity for FVIII:C and over 90% for FIX:C for up to 48 h. Intermittent decrease of FVIII:C or FIX:C was not observed, suggesting no adsorption of FVIII or FIX onto plastic surfaces during either short or long-term exposure. No thrombogenic components were detected in the high purity FIX concentrate. Thus, under the in vitro conditions used, FVIII/vWF and FIX were found to be suitable for administration by continuous infusion.

Blood Coagulation Tests