Tumor temperature distributions predict hyperthermia effect.

Abstract

Review of clinical hyperthermia (HT) trial results shows that there previously has not been a robust model relating efficacy of HT treatments to characteristics of the temperature distribution. Lack of a model has been an impediment in Phase II trials; these trials must include defining the prescription for HT treatment, optimizing the schedule of HT treatments, and defining quality assurance procedures. We propose a model that is based upon noting that the majority of a tumor volume is contained in the outermost "shell" of a solid tumor, across which shell the radial temperature distribution is assumed to be linear. Any linear distribution can be defined by coordinates of a point and a slope, and we choose the temperature at the radiographically defined edge of a tumor and the slope (dT/dr) across the outer shell as these determinants of the linear radial temperature distribution. A discriminant analysis of success or failure of treatment can then be based upon these two descriptors (Tedge, dT/dr). We have tested this model using data from patients with soft tissue sarcoma (Stage IIB or greater) that have entered an ongoing prospective trial of conventional preoperative radiotherapy (5000 cGy/25 Fx/5 wk) together with HT, the latter randomized to be given once or twice weekly during the 5 week course. Wide local excision of the primary tumor is done 1 month after completion of radiotherapy, and the extent of histologic change in the resected specimen is scored. Our model has an 86% predictive value for lack of complete or nearly complete necrosis in the resected specimen according to whether the time-averaged Tedge and slope during each HT treatment satisfy the equation Tedge + 1.2 (slope in degree C/cm) less than or equal to 40.6 degrees C in all but one treatment at most. Conversely, in 85% of cases with complete or nearly complete tumor necrosis, temperature distributions satisfied Tedge + 1.2 (slope in degree C/cm) greater than 40.6 degrees C during at least one HT treatment. Requiring greater than or equal to one third of treatments of a patient to satisfy the preceeding discriminant equation resulted in 80% of patients being correctly classified as a responder or nonresponder, with only one false positive prediction (patient incorrectly classified as a responder). The model can reveal systematic changes in the edge temperature distribution during the treatment course that are consistent with tumor perfusion changes inferred and measured by independent means.(ABSTRACT TRUNCATED AT 400 WORDS)

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J R Oleson, M W Dewhirst, J M Harrelson, K A Leopold, T V Samulski, C Y Tso. 1989. Tumor temperature distributions predict hyperthermia effect.. https://doi.org/10.1016/0360-3016(89)90472-0

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Thermographic assessment of inferior alveolar nerve injury in patients with dentofacial deformity.

PURPOSE: The purpose of this study was to evaluate the injury and recovery of the inferior alveolar nerve in orthognathic patients at 1 and 4 weeks after surgery using electronic thermography. MATERIALS AND METHODS: Twenty subjects with Class III dentofacial deformity were studied. All patients underwent bilateral sagittal split ramus osteotomy. To image the temperature of the face, 1 anteroposterior view and 1 lateral view were taken from both the right and left sides. Similar images were taken at 1 and 4 weeks after surgery. The control was the presurgical temperature of the 20 patients who showed unilateral or bilateral nerve damage after surgery. RESULTS: In the patients with unilateral nerve damage (n = 14), on the anteroposterior views, the temperatures of the mentum on the 2 sides differed by 0.64 degrees C at 1 week after surgery, and the difference decreased to 0.23 degrees C at 4 weeks after surgery. On the lateral images, the differences in temperature between the mentum areas were 0.10 degrees C at 1 week and 0.27 degrees C at 4 weeks after surgery. In the patients with bilateral nerve injury (n = 6), on the anteroposterior views, the temperatures of the mentum on the 2 sides differed by 0.20 degrees C at 1 week after surgery and 0.13 degrees C after 4 weeks. On the lateral views, the differences were 0.18 degrees C at 1 week and 0.34 degrees C at 4 weeks after surgery. Using the repeated measurement analysis method, the anteroposterior view showed statistically significant results in the patients with unilateral nerve damage. CONCLUSION: The infrared body temperature method is an objective method that can be applied as a supplemental diagnostic method for inferior alveolar nerve injury.

Body Temperature↗

The ingestible telemetric body core temperature sensor: a review of validity and exercise applications.

An ingestible telemetric temperature sensor for measuring body core temperature (Tc) was first described 45 years ago, although the method has only recently gained widespread use for exercise applications. This review aims to (1) use Bland and Altman's limits of agreement (LoA) method as a basis for quantitatively reviewing the agreement between intestinal sensor temperature (Tintestinal), oesophageal temperature (Toesophageal) and rectal temperature (Trectal) across numerous previously published validation studies; (2) review factors that may affect agreement; and (3) review the application of this technology in field-based exercise studies. The agreement between Tintestinal and Toesophageal is suggested to meet our delimitation for an acceptable level of agreement (ie, systematic bias <0.1 degrees C and 95% LoA within +/-0.4 degrees C). The agreement between Tintestinal and Trectal shows a significant systematic bias >0.1 degrees C, although the 95% LoA is acceptable. Tintestinal responds less rapidly than Toesophageal at the start or cessation of exercise or to a change in exercise intensity, but more rapidly than Trectal. When using this technology, care should be taken to ensure adequate control over sensor calibration and data correction, timing of ingestion and electromagnetic interference. The ingestible sensor has been applied successfully in numerous sport and occupational applications such as the continuous measurement of Tc in deep sea saturation divers, distance runners and soldiers undertaking sustained military training exercises. It is concluded that the ingestible telemetric temperature sensor represents a valid index of Tc and shows excellent utility for ambulatory field-based applications.

Body Temperature↗