PubMed Health⌕ Search

PubMed · 2647342

Rigid fixation: variations in osteotomy design and technique.

Abstract

The application of rigid fixation devices has expanded the craniomaxillofacial surgeon's armamentarium and allows greater versatility of osteotomy design and fixation. Further studies are under investigation to determine the degree of "interference" with growth as a result of application of rigid fixation devices. Our preliminary thought is that bone is dynamic and "liquid" enough to allow the driving forces of the developing cerebral tissue to remodel and recontour the bone tissue into a normal configuration and contour. Problems with relapse and resorption appear greatly reduced for both bone grafts and bone flaps. As the biomaterials industry continues to perfect rigid fixation devices, further advances will be forthcoming.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C R Dufresne. 1989. Rigid fixation: variations in osteotomy design and technique.. https://pubmed.ncbi.nlm.nih.gov/2647342/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Stacked plating for metadiaphyseal fractures of the distal radius: a technique report.

Combined injuries of the distal radius and shaft are rare, are usually caused by high energy, and pose a surgical dilemma. Surgical tactics and implants that are routinely used either for isolated fractures of the distal radius or for fractures of the radial shaft are often not applicable for this combined injury. We describe a technique of dual-stacked plating for these metadiaphyseal fractures and its use in two patients.

Bone Plates↗

Plate fixation of olecranon osteotomies.

The management of intra-articular distal humeral fractures remains a difficult surgical problem. Although an olecranon osteotomy provides excellent exposure for management of these fractures, a number of complications can occur after the creation and repair of the osteotomy including nonunion, malunion, hardware failure, and pain secondary to prominent hardware. In an effort to reduce the incidence of these complications, the senior authors now use contoured 3.5 mm reconstruction plates for the fixation of their apex-distal chevron olecranon osteotomies. Two surgeons at a single institution used this technique of exposure on a series of 17 consecutive patients with intra-articular distal humerus fractures between 1996 and 1999. In this series, all osteotomies united. There was one complication related specifically to the osteotomy: one of the screws in the plate penetrated the proximal radioulnar joint, interfering with forearm rotation; a second procedure was required to shorten the screw. Only one of the 17 patients requested plate removal during the 32 month (average) follow-up period. Plate fixation of olecranon osteotomies using a 3.5 mm reconstruction plate provides a construct with predictable healing and few complications. The overall results using this technique are comparable with other reported methods in the literature.

Bone Plates↗