PubMed Health⌕ Search

PubMed · 2665129

Pulmonary function testing: sources of error in measurement and interpretation.

Abstract

Valid pulmonary function data require that attention be paid to issues that can lead to errors in measurement or in interpretation. Routine procedures designed to reduce errors should be established. Among the most important of these are (1) assuring the accurate measurement and calculation of lung function parameters, which requires attention to accuracy when an instrument is brought into service in a laboratory and again when it is updated; (2) selecting reference equations and lower limits of normal appropriate for the patients being studied and for the equipment being used; (3) avoiding the errors introduced by using an excessive number of measurements in generating an interpretation; and (4) avoiding interpretation of results without considering the clinical setting and the pertinent elements of a complete data base.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R O Crapo, A H Morris. 1989. Pulmonary function testing: sources of error in measurement and interpretation.. https://pubmed.ncbi.nlm.nih.gov/2665129/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Tip cooling effect and failure mechanism of field-emitting carbon nanotubes.

The cooling effect accompanying field electron emission has been considered for a single carbon nanotube (CNT) used as a field emission (FE) electron source. An improved model for the failure mechanism of field emitting CNTs has been proposed and validated. Our model predicts a maximum temperature (T-max) located at an interior point rather than the tip of the CNTs, and the failure of the CNT emitters tends to take place at the T-max point, inducing a segment by segment breakdown process. A combination of Joule heating and electrostatic force effect is proposed responsible for initiating the failure of the field emitting CNT and validated by in situ FE observation.

Equipment Failure↗

[Importance of an initial check-up for diagnostic radiology apparatus management].

The management of apparatus for diagnostic imaging is an important job for radiological technologists. In the last 10 years we have encountered 2227 malfunctions in 3652 days. We detected 163 cases at the initial check-up, which accounted for 7.3% of total cases. By performing an initial check-up, we detected one malfunction every 21 days and were able to keep the effects of mishaps to a minimum, prevent accidents, and obtain stable-quality images.

Equipment Failure↗