Pancreatic function testing. Methods to identify exocrine insufficiency.

Abstract

The diagnosis of chronic pancreatitis is ideally established by an appropriate clinical history and confirmatory radiologic imaging. However, in cases where imaging results are normal or equivocal, pancreatic function testing is necessary. Direct (intubation) tests are generally accepted as the best methods for study of pancreatic exocrine capacity, but indirect tests, which are well tolerated and generally simple to perform, are gaining interest. Their shortcoming is that they are too insensitive to reliably differentiate patients with early exocrine dysfunction (ie, before malabsorption has occurred) from controls. Sensitivity is not improved by combining two or more studies. However, several modified tests (eg, two-stage paraaminobenzoic acid test, pancreolauryl test) have improved specificity and are able to distinguish pancreatic from other causes of steatorrhea. Their reproducibility in individual cases is of value in sequential studies and in patients with established pancreatic exocrine deficiency to seek evidence of improvement or deterioration in function and to determine patient compliance with replacement therapy.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N H Gilinsky. 1989. Pancreatic function testing. Methods to identify exocrine insufficiency.. https://doi.org/10.1080/00325481.1989.11704362

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

5-HT4 receptors, present in piglet atria and sensitive to SDZ 205-557, are absent in papillary muscle.

Putative 5-HT4 receptors were investigated in isolated piglet left atria and papillary muscles. In atrial tissues, 5-hydroxytryptamine (5-HT) was a potent positive inotropic agent with a pD2 of 6.7. Its effects were antagonised in a selective and competitive manner by the 5-HT4 receptor antagonist, SDZ 205-557, with a pA2 of 7.3. In contrast to atrial tissues, piglet papillary muscles were virtually unresponsive to 5-HT 10(-8)-10(-3) M, suggesting that functional cardiac 5-HT4 receptors are not present in ventricular tissue.

4-Aminobenzoic Acid

The BT-PABA/PAS test in tropical diabetes.

A 'screening' test is needed to identify patients with chronic pancreatitis among diabetics in tropical field surveys. We have examined the potential diagnostic yield of the BT-PABA/PAS test of exocrine pancreatic function in this setting. The recoveries of both PABA and PAS in eight healthy controls from Madras, south India, were lower than in controls from Manchester, north west England (mean +/- S.D., 51 +/- 11 vs. 79 +/- 7%, P < 0.001 for PABA; 52 +/- 11% vs. 81 +/- 7%, P < 0.001 for PAS) but the % PABA/PAS excretion index (PEI) was similar (0.96 +/- 0.14 vs. 0.96 +/- 0.06). Using a cut-off value of 0.75 for the PEI in a study group including eight patients with chronic pancreatitis and 26 with primary forms of diabetes, test sensitivity was 75%, specificity 92%, positive predictive value 75%, negative predictive value 92% and efficiency 88%.

4-Aminobenzoic Acid

The quantitative analysis of endogenous folate catabolites in human urine.

In man folates are catabolized and excreted as inactive cleaved degradation products, a mixture of pteridines and p-aminobenzoylglutamate (pABGlu) or its acetamido derivative (apABGlu). The daily rate of excretion represents the inescapable use of the vitamin in metabolic activity and thus has implications for determining the recommended dietary allowance for the vitamin. Furthermore, the rate of catabolism has been suggested to rise during pregnancy and in certain disease states. A method is described for the quantitative extraction and assay of the folate catabolites pABGlu and apABGlu in human urine. Aliquots of 24-h urine collections are acidified and applied to columns of Dowex 50W cation-exchange resin. The catabolites are selectively batch-eluted with increasing concentrations of HCl. The fraction containing pABGlu is diazotized and then applied to a C18 Sep Pak column for further purification and concentration. The fraction containing apABGlu was deacetylated and reapplied to the Dowex column and then treated identically to the pABGlu fraction. The methanolic concentrates of both extracts were evaporated to dryness and reconstituted with water and pABGlu was regenerated by reductive cleavage of the diazotized material with Zn/HCl. The extracts of the two catabolites were separated by reverse-phase HPLC using a Radial Pak C18 column. Recovery of isolated material was monitored by the addition of high specific activity tritiated labels of both compounds added as internal standards to all urine aliquots prior to purification and analysis.

4-Aminobenzoic Acid