PubMed Health⌕ Search

PubMed · 2670771

Mixed venous oximetry.

Abstract

We now have the technology through reflectance spectrophotometry to evaluate and display continuously mixed venous oxygen saturation SvO2 through use of a modified pulmonary artery catheter. Adding this method of assessing the balance of oxygen supply and demand to our standard armamentarium of hemodynamic monitoring may improve our ability to diagnose and treat cardiovascular aberrations at an earlier stage than was previously possible. Through analysis of the Fick equation, it can be seen that SvO2 depends upon the cardiac output, the arterial oxygen saturation, the hemoglobin level, and the rate of oxygen consumption. These are, in turn, affected by a great number of factors (see Fig 8). As seen in the variety of patient care examples cited above, the usefulness of SvO2 monitoring continues to grow. It appears that there are no intrinsic risks associated with SvO2 monitoring beyond those of customary PA monitoring. This new technology provides us with online information not previously available, at an associated cost that needs to be further examined.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

I A Kupeli, P R Satwicz. 1989. Mixed venous oximetry.. https://doi.org/10.1097/00004311-198902730-00007

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Perception of training needs and opportunities in advanced airway skills: a survey of British and Irish trainees.

BACKGROUND AND OBJECTIVE: We surveyed delegates at the Group of Anaesthetists in Training (UK) meeting to investigate evidence of a training-gap (number of fibreoptic intubations believed to bestow competence vs. number actually performed). METHODS: Questionnaires were distributed to and collected from delegates in person. Questions covered six areas, including experience of fibreoptic intubation and cricothyrotomy, fibreoptic intubation as a specialist skill and ethical issues. RESULTS: We received 221 replies (76%). All trainees believed competence to be achievable with 10 intubations (interquartile range (IQR) 10-20); the median number performed was 2 (IQR 0-4). This was statistically significant for the groups' senior house officers, 1st and 2nd year registrars and 3rd and 4th year registrars; P < 0.0001. Many final year trainees (12/20, 60%) also failed to achieve their competency target. Few trainees had seen or performed any cricothyrotomies (medians 0, IQRs 0-1 and 0-0). Most (195/208, 94%) believed that fibreoptic intubation was a core skill and 199/212 (94%) believed that all should be competent by completion of training. Ten percent (n = 208) felt it unethical to perform an awake training intubation with full consent and 10% believed it acceptable without explanation. Most (82.7%) would fibreoptically intubate an asleep patient (requiring intubation) without consent. CONCLUSION: Trainees reported a gap between their perception of competence and achievement in awake fibreoptic intubation. Simple and complex simulations and structured training programmes may help. Anaesthetists must address the ethics of clinical training in advanced airway management.

Anesthesiology↗