PubMed Health⌕ Search

PubMed · 2700281

[Basic experiments on denture rigidity at various types of palatal bars].

Abstract

UNLABELLED: The purpose of this study was to investigate the rigidity of removable partial denture with a palatal bar. A metal model with a Kennedy Class II-modification 1, was fabricated as a simulated dental arch. The model palate was adjustable to three different radii (17.5 mm, 20.0 mm and 22.5 mm) on the frontal section. MATERIALS: These were bending palatal bars and preformed plastic patterns. One of the bending palatal bars was 3.4 mm wide 1.4 mm thick, the other was 3.1 mm wide and 1.1 mm thick. Two other bars, 5.0 mm wide, 1.7 mm thick and 5.0 mm wide, 1.5 mm thick, were cast in Ticonium p-100 alloy from the plastic pattern. METHOD: The materials were fitted to the model and rigidity was measured by loading at various parts equivalent to the distal extension base. The experiments were performed with a 1 mm space between the frames and the model and again with a 1 mm thick sheet of mercaptan rubber-base impression material between them. RESULTS: 1. Cast palatal bars showed a smaller deflection than the bending palatal bars. 2. The bending palatal bars showed a large deflection of the distal extension base. So, care should be exercised when fitting a bending palatalbar in a distal extension case because of the incompressibility of the mucous membrane. 3. Bar deflection was only slightly different for the three types of palate. 4. Deflection of the palatal bar and distal extension base was smaller when the bar was thicker and wider. 5. The amounts of palatal bar and base deflection with the 1.0 mm space was in proportion to the load. 6. With the rubber-base sheet between, the amounts of deflection was not proportional to the load, and the amount of deflection under a 30 kg load was almost twice that of a 5 kg load.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Tanaka. 1989. [Basic experiments on denture rigidity at various types of palatal bars].. https://pubmed.ncbi.nlm.nih.gov/2700281/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Case report of a patient with bounded missing, treated with removable partial denture].

PATIENT: The patient was a 60-year-old male with the chief complaint of loosening of the bridge on the upper right side. The diagnoses of the patient were detachment of the bridge (7 6 5 4 3 2 1 | 1) and root fracture (5|). A cobalt chromium plate with Mini-SG attachment was used at 4 3 2| to fix the bridge. The course of the patient was uneventful five years after the treatment. DISCUSSION: Judging from the condition of the detached bridge, the same type of fixed bridge was considered too weak to withstand the lateral force. Stabilization of the functional occlusion was achieved by using the attachment, followed by good clinical results. CONCLUSION: The patient was satisfied with the comfort of the removable partial denture with attachment, and good functional results were obtained.

Denture Design↗