PubMed Health⌕ Search

PubMed · 270596

[A study on ventilation with different types of flow patterns (author's transl)].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Mima, H Takamura, M Muneyuki. 1977. [A study on ventilation with different types of flow patterns (author's transl)].. https://pubmed.ncbi.nlm.nih.gov/270596/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Best compliance during a decremental, but not incremental, positive end-expiratory pressure trial is related to open-lung positive end-expiratory pressure: a mathematical model of acute respiratory distress syndrome lungs.

A mathematical model of the acute respiratory distress syndrome (ARDS) lung, incorporating simulated gravitational superimposed pressure and alveolar opening and closing pressures, was used to study the mean tidal pressure-volume (PV) slope ("effective compliance") during incremental and decremental positive end-expiratory pressure (PEEP) trials with constant tidal volume (VT) "ventilation." During incremental PEEP, the PEEP giving maximum mean tidal PV slope did not coincide with "open lung PEEP" (minimum PEEP preventing end expiratory collapse of 97.5% of alveoli inflated at end-inspiration), and it varied greatly with varying VT and "lung mechanics." Incremental PEEP with a low VT tests recruitment by the peak pressure, not prevention of collapse by PEEP. During decremental PEEP with a low VT, maximum mean tidal PV slope occurred with PEEP 2-3.5 cm H2O below open-lung PEEP, unless closing pressure was high. High VT, high "specific compliance," and high opening pressures caused slightly greater underestimation of open-lung PEEP. Maximum mean tidal PV slope was always higher (e.g., 93.7 versus 16.69 ml/cm H2O), and the variation in PV slope with PEEP was greater, during decremental PEEP. The maximum PV slope during a decremental PEEP trial with a low VT may be a useful method to determine open-lung PEEP in ARDS, and should be studied clinically.

Lung Compliance↗

Evaluation of some alternative mechanisms for interface-related stress relaxation in lung.

Lung surfactant might exchange reversibly between the alveolar gas-liquid interface and the liquid lining layer. This solubilization process could then contribute to time-dependent pulmonary mechanical phenomena. Theoretical analysis of a model alveolus shows how solubilization can produce recoil pressure relaxation of the lung. The analysis shows that for most experimental observations reported the solubilization kinetics probably could not have been determined by the actual fitting in, or squeezing out, of surfactant in the surface film. Most data are consistent with a solubilization rate controlled by diffusion in the liquid sublayer. However, in order for a diffusion-controlled mechanism to be significant the diffusing substance should be large, such as a micelle, and the alveolar liquid layer should be at least 1 micrometer thick. These conditions are quite realistic for slightly edematous lungs and thus might apply to many experimental, or pathological, situations.

Lung Compliance↗