Polyurethane elastomers for facial prostheses.

Abstract

A review of the polyurethane elastomers used for facial prostheses has been presented. A description of the casting technique was given. The materials require accuracy and care in handling to insure the successful casting of a prosthesis. They seem to simulate the characteristics of the facial tissues and are more durable and comfortable than previously used materials. Over 300 patients have been exposed to or treated with these materials without evidencing significant adverse tissue reaction. In spite of the improvements that these materials present over previous ones (PVC and silicones), much work is still required to understand their behavior and their physical and mechanical characteristics and to compensate for the metameric phenomenon.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J B Gonzalez. 1978. Polyurethane elastomers for facial prostheses.. https://doi.org/10.1016/s0022-3913(78)80018-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Value of routine follow-up after infrainguinal arterial reconstruction].

Longterm patency of infrainguinal bypass procedures may be established on the basis of clinical evaluation and ankle pressure measurements. With the aim of assessing whether these parameters could predict grafts at risk for occlusion, we identified 24 patients in whom the bypass had occluded between 3 and 12 months postoperatively, but following at least one follow-up. These patients were compared with a control group consisting of further 24 patients operated on during the same period, but in whom the bypass was patent. Prior to graft occlusion only nine (39%) patients had complained of claudication, and a significant drop in ankle pressure was demonstrated in seven (29%) patients. These figures were significantly higher than the one (4%) patient in the control group who complained of claudication and the other (4%) patient who developed a drop in ankle pressure (p < 0.02 and 0.05, respectively). Graft surveillance based on patients' history and ankle pressure measurements are insufficient parameters for identification of grafts at risk for occlusion. However, the occurrence of claudication and/or a significant drop in ankle pressures are associated with a high incidence of graft thrombosis.

Biocompatible Materials

[Implantation of a Stecker metal prosthesis in malignant stenosis of the gastric stump].

A 55 year old patient 3 years after gastric resection (Billroth II) has got gastric outlet stenosis. Half year ago was established a tumour recidive, that the time of reoperation was inoperable. Under endoscopic and radiological control we have introduced and placed a 19 mm diameter, 4 cm long balloon expandable tantalum stent (Strecker stent). The gastric passage has normalised and after 6 month the patient is symptom free.

Biocompatible Materials