PubMed Health⌕ Search

PubMed · 2771614

Visual orientation estimation.

Abstract

A systematic error is reported in orientation estimation, in that on average, estimates are closer to the vertical axis than are the stimuli by up to 6 degrees. This systematic error results from a specific mechanism that may be related to depth perception, and that is avoided in certain circumstances or when other mechanisms take over. For example, the estimates of one observer who was a well-trained professional draughtsman did not show this systematic error. Furthermore, for all observers tested, estimation of clock time is not subject to the regular orientation estimation error. Rather, observers tend to estimate times as slightly further from the quarter hour than they really are. Orientation judgement channel capacity was also studied under various conditions. The number of discriminable orientations is far above the magic number "7" limit, reaching over 20 in optimal circumstances. The distribution of discriminable orientations is nonlinear, in that these are more closely packed about the horizontal and vertical axis than at the oblique.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Dick, S Hochstein. 1989. Visual orientation estimation.. https://doi.org/10.3758/bf03208083

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A low glycaemic index breakfast cereal preferentially prevents children's cognitive performance from declining throughout the morning.

This study investigated whether the glycaemic index (GI) of breakfast cereal differentially affects children's attention and memory. Using a balanced cross-over design, on two consecutive mornings 64 children aged 6-11 years were given a high GI cereal and a low GI cereal in a counterbalanced order. They performed a series of computerised tests of attention and memory, once prior to breakfast and three times following breakfast at hourly intervals. The results indicate that children's performance declines throughout the morning and that this decline can be significantly reduced following the intake of a low GI cereal as compared with a high GI cereal on measures of accuracy of attention (M=-6.742 and -13.510, respectively, p<0.05) and secondary memory (M=-30.675 and -47.183, respectively, p<0.05).

Attention↗

Inhibitory control test is a simple method to diagnose minimal hepatic encephalopathy and predict development of overt hepatic encephalopathy.

OBJECTIVES: To compare inhibitory control test (ICT), a simple/rapid test of attention, to a standard psychometric battery (SPT) to diagnose minimal hepatic encephalopathy (MHE) and predict development of overt hepatic encephalopathy (OHE) in cirrhotic patients. METHODS: Fifty nonalcoholic cirrhotics and 50 age/educational-status-matched controls were given ICT and SPT in the same sitting. Performance impaired beyond two standard deviations of controls was considered MHE in cirrhotics. ICT results (lure/target response and lures/person) were compared between controls and cirrhotics and within cirrhotics with/without MHE. Receiver-operating characteristic analysis was used to study ICT for MHE diagnosis. Twenty subjects were administered SPT and ICT twice to assess test-retest reliability. All cirrhotics were followed routinely for the development of OHE. RESULTS: Cirrhotics performed worse than controls on SPT and ICT. Using SPT, 39 cirrhotics had MHE. ICT was administered faster than SPT (15 vs 37 min). Cirrhotics with MHE had significantly higher lure (28%vs 3%) and lower target response (91%vs 96%) compared with those without MHE. Lure/person >5 had 90% sensitivity/specificity for MHE diagnosis. AUC for receiver-operating characteristic for lures alone was 95.8%. Lure and target responses were highly correlated (r= 0.9) between sessions showing high test-retest reliability. Five (10%) patients developed OHE on f/u of 26 +/- 10 months; all five had been diagnosed with MHE using ICT and SPT. None of the five patients with discordant results on SPT and ICT developed OHE. CONCLUSIONS: ICT has good sensitivity/specificity for MHE diagnosis, is reliable and is equivalent to SPT for predicting OHE development.

Attention↗