[Clinical study on sweep-frequency tympanometry--data analysis using principal component analysis].

Abstract

A sweep-frequency tympanometer has been developed to diagnose auditory ossicular lesions more precisely. This device measures acoustic middle ear features by changing the probe tone frequency continuously. The oscillator sweeps frequency of the probe tone from 200 to 2,500Hz 1.5 seconds. A microphone picks up the changes in the acoustic pressure and the phase in the external auditory meatus during the frequency change of the probe tone. These measurements are performed under pressures at -200 and 0 dapa, and differences of both the acoustic pressure and the phase between these two pressures are graphically displayed using a microcomputer. This device can also measure and digitally display the frequency (BHz) and the sound pressure (BdB) at the minimum point (B) of the sound pressure curve, the frequency (ZHz) at 0 crossing point (Z) of the sound pressure curve, and the frequency (PHz) and the phase difference (Pdeg) at the maximum point (P) of the phase curve. Normal ranges of these five values were obtained to establish diagnostic criteria from 200 normal ears. The normal values were as follows: BHz, 480 to 1,070Hz; BdB, -6.0 to -1.8dB; ZHz, 1,100 to 1,860Hz; PHz, 910 to 1,820Hz; and Pdeg, 16.3 to 47.9 degrees. Eight cases of ossicular dislocation and 14 cases of ossicular fixation, all of which had normal external auditory meatus and tympanic membrane, were evaluated based on these values. All the cases with ossicular dislocation and 12 cases out of 14 with ossicular fixation were correctly diagnosed.(ABSTRACT TRUNCATED AT 250 WORDS)

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T Terada. 1989. [Clinical study on sweep-frequency tympanometry--data analysis using principal component analysis].. https://doi.org/10.3950/jibiinkoka.92.923

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[An electromechanical model of the middle ear].

A dynamic model of the middle ear and mastoid system was designed in order to evaluate basic principles in tympanometry. The model allows controlled simulation of the exact changes in the ear drum's mass and in intratympanic volume and pressure. The contribution of each of these factors to acoustic impedance was measured. We found that the volume values of static, acoustic compliance were equal to the volume of air in a closed cell. There was good correlation between direct measurement of air pressure in the model cell and indirect pressure measurement by tympanometry. We also demonstrated a difference between mechanical displacement of the drum and its displacement by negative pressure. This demonstration of tympanometry using a middle-ear compatible model enables us to understand its principles and helps in the education of students.

Acoustic Impedance Tests

Diagnostic value of microtympanometry in primary care.

OBJECTIVE: To determine the reliability, validity, and feasibility of a new hand held microtympanometer. DESIGN: Comparison of microtympanometry by two independent observations of a general practitioner and a nurse, and against a validated reference instrument. SETTING: Primary care health centre of a school for the deaf in the United States. SUBJECTS: 111 schoolchildren receiving a regular check up. MAIN OUTCOME MEASURES: Tympanometry with the Grason Stadler 28, classified with a slightly modified Jerger's classification. RESULTS: Interobserver reliability was 0.95 (Cohen's kappa). Results of microtympanometry were highly comparable with results of the reference instrument (likelihood ratio of positive results, 161.2). CONCLUSIONS: The microtympanometer could be used in general practice: it is hand held, child friendly, easy to handle, and accurate.

Acoustic Impedance Tests