PubMed Health⌕ Search

PubMed · 2904512

Quantitative immunocytochemistry using an image analyzer. II. Concentration standards for transmitter immunocytochemistry.

Abstract

Image analyzers can measure both the optical density and geometry of immunocytochemically labeled cells and fibers, as reviewed in a companion paper (Mize et al., 1988). In this paper, we report a procedure which allows us to estimate the concentration of a neurotransmitter based upon the optical density of antibody labeling produced by immunocytochemistry. To accomplish this, we developed a standard which binds conjugated neurotransmitters. Several artificial media for the standard were compared, including agar, gelatin, and agar-gelatin. A 3% agar matrix was found to be most suitable because it cut well and was nearly transparent. The agar sections were activated with cyanogen bromide/acetonitrile to promote coupling to the antigen. To test the standard, we used gamma-aminobutyric acid (GABA) conjugated to bovine serum albumin (BSA) as the antigen. The antibody was directed against this conjugate. Activated agar sections were incubated in serial dilutions of the tritium-labeled GABA/BSA conjugate. The radioactivity of some of these sections was measured to estimate the amount of coupled antigen. The remaining sections were incubated in the GABA antibody and processed for immunocytochemistry. The optical density of these sections was measured with an image analyzer. A linear relationship was found between GABA concentration and optical density over a range of at least 0.01 to 1 nmol/mg of agar. These results show that the concentration of bound GABA can be estimated from the optical density of sections labeled by antibody immunocytochemistry. The applicability of this technique to fixed brain tissue is discussed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L B Nabors, E Songu-Mize, R R Mize. 1988. Quantitative immunocytochemistry using an image analyzer. II. Concentration standards for transmitter immunocytochemistry.. https://doi.org/10.1016/0165-0270(88)90126-4

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Rapid and accurate measurement for phase-change optical recording bits.

Conducting atomic force microscopy (CAFM) and scanning surface potential microscopy (SSPM) have been used to image the phase-change optical recording bits. Commercially available digital versatile discs (DVD) + rewritable (RW) with initialization process were measured in experiments. Comparing the measurement results of both, the measurement resolution of CAFM is far superior to that of SSPM. With the DVD + RW disc rotating at a linear speed of 3.5 m/s, appropriate writing laser power range, may be precisely identified by CAFM as 10-15 mW. This is sufficient to verify the high-resolution recording bits research method. This new method may also be applied to the development of new types of phase-change recording materials.

Image Processing, Computer-Assisted↗

Image analysis by pulse coupled neural networks (PCNN)--a novel approach in granule size characterization.

A biologically inspired spiking neural network model, the pulse coupled neural network (PCNN), has been applied for the first time in bulk particle characterization, and specifically in the characterization of pharmaceutical granule size distributions. The PCNN was trained on surface images of pharmaceutical granule beds, and the adjustable parameters (radius neuron interconnection, r0, linking weight coefficient, beta, local threshold potential, VTheta, and number of iterations) were successfully optimized using design of experiments. As demonstrated with size fractions of granules, it was found that the PCNN produced granule size-dependent signals. In general, a first highest and relatively narrow peak located in the region of two to twelve iterations corresponded to smaller particle size, while larger particles resulted in wider peaks and in highest (not first) peak at a range between 13 and 25 iterations. Better predictions, i.e. lower RMSEP (root mean squared error of prediction) values, were obtained using high beta value, low r0 and VTheta values, while the number of iterations had to exceed 110 and the optimized model (RMSEP lower than 5) corresponded to PCNN variables: r0=1, beta=0.4, VTheta=2, and number of iterations=150. The coefficient of determination (R2) of the model was 0.94 and the predicted variation (Q2) was 0.91, while the Pearson correlation coefficient between the predicted and the measured mean particle size by sieving for eight test batches was 0.98. These findings could be characterized as promising and encouraging for the further use of image analysis by PCNNs in pharmaceutical bulk particle size and shape characterization.

Image Processing, Computer-Assisted↗

Production of siRNA- and cDNA-transfected cell arrays on noncoated chambered coverglass for high-content screening microscopy in living cells.

In this chapter, we provide a protocol for the production of transfected cell arrays in living mammalian cells on noncoated chambered coverglass for the systematic functional analyses of human genes by high-content screening microscopy. This method should facilitate drug target validation by small-interfering RNAs.

Image Processing, Computer-Assisted↗