PubMed · 2904713
Analytical problems encountered during high-performance liquid chromatographic separation and coulometric detection of bopindolol metabolites in human plasma.
Abstract
Good clinical control of hypertension is achieved with low doses of the potent beta-blocker bopindolol. Pharmacokinetic evaluations therefore require an analytical technique of high sensitivity. Analysis of plasma by high-performance liquid chromatography (HPLC) using electrochemical detection provides this sensitivity. This article describes the development of an analytical procedure and presents a reversed-phase HPLC method with coulometric detection suitable for plasma analyses during pharmacokinetic investigations of bopindolol therapy.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
S L Perkins, B Tattrie, P M Johnson, E Z Rabin. 1988. Analytical problems encountered during high-performance liquid chromatographic separation and coulometric detection of bopindolol metabolites in human plasma.. https://doi.org/10.1097/00007691-198804000-00019