Practical neutron dosimetry with superheated drops.

Abstract

The Superheated Drop Detector (SDD) is a new kind of neutron detector based on the same principle as that of the bubble chamber, except the superheated material is in drop form suspended by a gel or polymer as first described by Apfel (U.S. Patent 4,143,274). Previously, we have developed a theoretical model for the prediction of the threshold neutron energy to nucleate bubbles in our superheated materials and a model for the calculation of the energy dependent response function of SDD. The results of the theoretical calculations agree with the experimental measurements reasonably well. We found the measured response curve of one of our SDDs follows the same trend as the ideal ICRP dose equivalent response curve within 40% for neutrons of energy above 100 keV and within a factor of 10 below 100 keV. Therefore, it is possible to make a rem-response Superheated Drop Detector. We have further calibrated our SDD with 252Cf neutron sources (both bare and D2O moderated). The results are in reasonable agreement with our theoretical predictions, which proves that our model is valid not only for monoenergetic neutrons but also for neutrons from a radioactive source. The principles of operation of our detector, which can be used in neutron dosimetry, area monitoring, and neutron spectrometry, are discussed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R E Apfel, Y C Lo. 1989. Practical neutron dosimetry with superheated drops.. https://doi.org/10.1097/00004032-198901000-00007

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Nuclear data for production of the therapeutic radionuclides 32P, 64Cu, 67Cu, 89Sr, 90Y and 153Sm via the (n,p) reaction: evaluation of excitation function and its validation via integral cross-section measurement using a 14 MeV d(Be) neutron source.

Nuclear data for production of the therapeutic radionuclides 32P, 64Cu, 67Cu, 89Sr, 90Y and 153Sm via (n,p) reactions on the target nuclei 32S, 64Zn, 67Zn, 89Y, (90)Zr and 153Eu, respectively, are discussed. The available information on each excitation function was analysed. From the recommended data set for each reaction the average integrated cross section for a standard 14 MeV d(Be) neutron field was deduced. The spectrum-averaged cross section was also measured experimentally. A comparison of the integrated value with the integral measurement served to validate the excitation function within about 15%. A fast neutron source appears to be much more effective than a fission reactor for production of the above-mentioned radionuclides in a no-carrier-added form via the (n,p) process. In particular, the possibility of production of high specific activity 153Sm is discussed.

Neutrons↗

Width of the hexadecane-water interface: a discrepancy resolved.

An existing discrepancy in the determined values of the width of the hexadecane-water interface as determined from X-ray reflection (XR) and recent neutron reflection (NR) measurements has been resolved. The NR-determined width reported here is 6.0 +/- 1.0 Angstroms, which compares extremely well with the XR-determined value of 6.0 +/- 0.2 Angstroms. The origin of the discrepancy has been attributed to the thermal history of the interface rather than sample purity or other technique-dependent reasons.

Neutrons↗