PubMed HealthSearch

PubMed · 2937518

Digital arthroplasty.

Abstract

Correction of digital deformities by an arthroplasty procedure is by far the most commonly used technique. However, the choice of procedure is complicated by contradictory methods described in many texts. The goal of surgery is to maintain as much function as possible, achieve a cosmetic result, and give the best prognosis for avoidance of recurrence.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A E Burns. 1986. Digital arthroplasty.. https://pubmed.ncbi.nlm.nih.gov/2937518/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Dye incorporation to enhance the laser ablation of standard and reduced-modulus bone cements.

Laser ablation of acrylic bone cement is an alternative method of cement removal that can be used during revision arthroplasty of cemented implants. This study investigated the feasibility of using a continuous-wave Argon ion laser (wavelength = 514 nm) with the addition of methylene blue or red dye no. 13 to enhance the ablation of two types of bone cements: polymethylmethacrylate and polybutylmethylmethacrylate. Six cement/dye combinations were studied while power (0.5, 0.75, and 1.0 W) and exposure times (30, 45, 60, and 90 seconds) were varied. The Argon laser was unable to ablate undyed polymethylmethacrylate or polybutylmethylmethacrylate. However, ablation was shown for both cements with either dye. The red dye had a stronger absorption peak at 514 nm than did the blue dye. Statistically larger ablation areas were seen for red polymethylmethacrylate than for blue polymethylmethacrylate (p < 0.013) at all levels tested. Ablation areas were larger in red than in blue polybutylmethylmethacrylate cement. Blue polybutylmethylmethacrylate cement produced larger ablation areas than did blue polymethylmethacrylate cements at all energy levels tested, with smaller surrounding damage areas. Red polybutylmethylmethacrylate cement also produced larger ablation areas than did red polymethylmethacrylate cement (at 0.75 and 1.0 W), again with smaller damage areas. Damage zones were smallest in red polybutylmethylmethacrylate cements at all test levels. These results suggest that, by using dyes to selectively alter the absorption characteristics of bone cement, laser ablation can be an effective method for cement removal. Changes in the chemical structure of the cement can also influence the response to laser treatment. Furthermore, the absorption spectra of the bone cement can be altered to maximize energy absorption at a wavelength that is not absorbed by bone tissue; this potentially minimizes damage to bone during revision surgery.

Arthroplasty

Total wrist arthroplasty: a quantitative review of the last 30 years.

OBJECTIVE: To investigate the suitability of design of 3 generations of wrist prostheses. METHODS: A comparative review was performed on the Swanson, Volz, Meuli, Trispherical, Biaxial, and MWP III total wrist prostheses. RESULTS: The review revealed a sharp rise in fracture and revision rates for the Swanson prosthesis after 55 months followup, with the most likely site for fracture at the junction of the distal stem and barrel. The Volz prosthesis had initial problems with a postoperative resting stance of ulnar deviation, due to the radial shift of the axis of the prosthesis to that of the normal wrist. A modified prosthesis corrected the problem of ulnar deviation; however, problems with bone resorption under the collar of the radial component and metacarpal loosening were seen. The majority of complications occurred in patients with post-traumatic degenerative joint disease. The remaining prostheses have had only a few clinical studies, and are presented to illustrate the different design concepts adopted. CONCLUSION: Total wrist arthroplasty has less satisfactory clinical outcomes compared to hip and knee arthroplasty. The changes in design from the first to the third generation, with closer approximation to the wrist joint's center of rotation, have led to encouraging results. The comparison of the clinical outcome of different prostheses has been difficult due to the lack of uniformity of outcome measures used.

Arthroplasty