Blood flow determinations utilizing digital densitometry.

Abstract

A method of obtaining relative and absolute blood flow measurements from digital densitometry was evaluated with a simulated vessel phantom and a hydrodynamic model. A digital vascular imaging system capable of acquisition in 512(2) and 1024(2) mode was used. Relative and absolute blood flow were measured using parameters derived from the densitometric curve. Since application of densitometric data to absolute flow measurements requires the vessel diameter, an algorithm for vessel size determination was created. Gray scale changes were demonstrated to be linearly related to contrast concentration. The variance of vessel size determination was significantly different in all combinations of 1024(2) and 512(2) imaging with 15 cm or 35 cm field size. The error in vessel size determination was significantly less using the larger 1024(2) matrix and the smaller 15 cm image intensifier field size, as shown by the smaller variance. In relative flow determinations, there was good correlation between the flow and four parameters of the densitometric curve with no significant differences between 512(2) and 1024(2) imaging. Absolute flow determinations had slightly lower correlation to actual flow but were not significantly different from relative flow determinations. Relative and absolute blood flow determinations can be performed adequately with either 512(2) or 1024(2) imaging. The increased accuracy in vessel size determination with 1024(2) imaging makes this high resolution system potentially preferable to determine absolute blood flow.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J F Lois, N J Mankovich, A S Gomes. Blood flow determinations utilizing digital densitometry.. https://pubmed.ncbi.nlm.nih.gov/2960362/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The structure of the zinc sites of Escherichia coli DNA-dependent RNA polymerase.

X-ray absorption spectroscopy is ideally suited for the investigation of the electronic structure and the local environment (approximately 5 A) of specific atoms in biomolecules. While the edge region provides information about the valence state of the absorbing atom, the chemical identity of neighboring atoms, and the coordination geometry, the extended x-ray absorption fine structure region contains information about the number and average distance of neighboring atoms and their relative disorder. The development of sensitive detection methods has allowed studies using near physiological concentrations (as low as approximately 100 microM). RNA polymerase from Escherichia coli contains two zinc atoms: one tightly bound in the beta' subunit, the subunit that participates in template binding, and the other loosely bound in the beta subunit, the subunit that participates in substrate binding. X-ray absorption studies of these zinc sites in the native protein and of the zinc site in the beta' subunit after removal of the zinc in the beta subunit site by p-(hydroxymercuri)benzenesulfonate (Giedroc, D. P., and Coleman, J. E. (1986) Biochemistry 25, 4969-4978) indicate that both zinc sites have octahedral coordination. The zinc in the beta' subunit site has four sulfur ligands at an average distance of 2.36 +/- 0.02 A and two oxygen (or nitrogen) ligands at an average distance of 2.23 +/- 0.02 A. The beta subunit zinc site has five sulfur ligands at an average distance of 2.38 +/- 0.01 A and one histidine nitrogen ligand at 2.14 +/- 0.02 A. These results are in general agreement with earlier biochemical and spectroscopic studies.

Absorptiometry, Photon

Bone gain in young adult women.

OBJECTIVE: To test whether bone mass increases in healthy nonpregnant white women during early adult life after cessation of linear growth; and to test whether various self-chosen levels of physical activity and nutrient intake or use of oral contraceptives influences this increase in bone mass. DESIGN: Longitudinal prospective study of up to 5 years of 156 healthy college-aged women full-time students attending professional schools in universities in the Omaha, Neb, area. SETTING: University medical center. PARTICIPANTS: A convenience sample of healthy women students from Omaha-area professional schools. Any candidate with an illness, condition, or medication (except oral contraceptives) thought to affect general health or bone mass was excluded. INTERVENTIONS: None. OUTCOME MEASURES: Clinical and family histories of disease, particularly osteoporosis; oral contraceptive use; bone mineral densities of the spine, forearm, and total body by dual- and single-photon absorptiometry; estimates of nutrient intake by repeated 7-day diet diaries; and measures of physical activity using a physical activity monitor. RESULTS: The median gain in bone mass for the third decade of life, expressed as a percentage per decade, was 4.8% for the forearm, 5.9% for lumbar bone mineral content, 6.8% for lumbar bone mineral density, and 12.5% for total body bone mass (P < .0001 in all cases). By both bivariate and multiple regression analysis the rate of gain in bone density of the spine was negatively correlated with age and positively correlated with calcium/protein intake ratio and physical activity (multiple r = .31; P = .004). Bivariate analysis showed that use of oral contraceptives was associated with greater gain in total body bone mass (r = .31, P = .01). The estimated age when mineral acquisition ceased ranged from 28.3 years to 29.5 years at the several study sites. CONCLUSIONS: Gain in bone mass occurs in healthy young women during the third decade of life. Physical activity and dietary calcium intake both exert a positive effect on this bone gain. Use of oral contraceptives exerts a further independent positive effect. Changes in life-style among college-aged women, involving relatively modest increases in physical activity and calcium intake, may significantly reduce the risk of osteoporosis late in life.

Absorptiometry, Photon

Extended x-ray absorption fine structure studies of a retrovirus: equine infectious anemia virus cysteine arrays are coordinated to zinc.

Zinc finger arrays have been established as a critical structural feature of proteins involved in DNA recognition. Retroviral nucleocapsid proteins, which are involved in the binding of viral RNA, contain conserved cysteine-rich arrays that have been suggested to coordinate zinc. We provide metalloprotein structural data from an intact virus preparation that validate this hypothesis. Extended x-ray absorption fine structure (EXAFS) spectroscopy of well-characterized and active preparations of equine infectious anemia virus, compared with a peptide with known coordination and in combination with available biochemical and genetic data, defines a Cys3His1 coordination environment for zinc. The average of the Zn-S distances is 2.30(1) A and that of the Zn-N distance (to histidine) is 2.01(3) A.

Absorptiometry, Photon