Doppler flow mapping and its comparison with the continuity equation method for quantifying aortic stenosis.

Abstract

The flow-mapping technique, which detects and planimeters the area of systolic flow at the site of the aortic orifice, was applied to 59 patients with a stenosed aortic valve, all of whom underwent cardiac catheterization. The success rate was 93%. The correlation coefficient between the values of valvular areas obtained by Doppler and those yielded by the Gorlin formula was r = 0.93 (SEE = 0.12 cm2). The continuity equation procedure, with the use of the velocity-time integrals, was applied sequentially to 20 of the above mentioned patients. The success rate was 85%. The valvular areas obtained in these patients by the Gorlin formula correlated well with those obtained with flow mapping (r = 0.90, SEE = 0.14, standard deviation of the difference = 0.13 cm2), as well as with those yielded by the continuity equation procedure (r = 0.86, SEE = 0.17 cm2, standard deviation of the difference = 0.16 cm2). Furthermore, the data from both ultrasonic methods were satisfactorily cross-correlated (r = 0.92, SEE = 0.12 cm2). It is noteworthy that the values of aortic valvular area obtained by Doppler were slightly larger than those found using either the continuity equation procedure or the Gorlin formula. The authors conclude that the flow-mapping technique represents a reliable method for quantifying stenotic aortic valvular area and correlates well with the continuity equation procedure. It is therefore suggested that, whenever possible, both techniques should be used sequentially as a valuable and practical cross-checking policy.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D Kalmanson, C Veyrat, C Gourtchiglouian, W el Yafi, D Sainte Beuve. 1988. Doppler flow mapping and its comparison with the continuity equation method for quantifying aortic stenosis.. https://doi.org/10.1093/eurheartj%2F9.suppl_e.93

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Transvalvular Flow Rate is Associated With Mortality Rate and Lifetime Loss in Aortic Valve Stenosis: A Meta-Analysis of Reconstructed Time-to-Event Data.

Low-flow states are associated with adverse outcomes in aortic stenosis (AS), but the prognostic value of transvalvular flow rate (TFR) has not been consistently established across studies. This study is a systematic review and meta-analysis of reconstructed time-to-event data was performed in accordance with Preferred Reporting Items for Systematic Reviews and Meta-analyses. PubMed/MEDLINE, EMBASE, and Cochrane Library were searched for studies (published by November 14, 2025) comparing low versus normal TFR in AS. Data were collected from Kaplan-Meier curves. The primary endpoint was all-cause mortality. Survival was assessed using pooled Kaplan-Meier curves, Cox regression, flexible parametric survival models, and restricted mean survival time (RMST) analysis. A total of 9 studies including 6,494 patients were analyzed; 2,575 (39.7%) had low TFR. At 8 years of follow-up, estimated survival was 34.1% (95% confidence interval [CI] 24.7% to 47%) in the low-TFR group and 63% (95% CI 58.9% to 67.4%) in the normal-TFR group. Low TFR was associated with higher all-cause mortality (hazard ratio 1.59, 95% CI 1.45 to 1.74, p < 0.001). We observed a progressively greater hazard over time, with the hazard ratio approaching 1.9 by 8 years. At 8 years, RMST in the normal-TFR group was 7.37 years (95% CI 7.21 to 7.53 years) versus 5.07 years (95% CI 4.91 to 5.23 years) in the low-TFR group, representing a lifetime loss of 2.3 years in the low-TFR group (&#x394;RMST -2.30 years, 95% CI -2.53 to -2.07 years, p < 0.001). In patients with AS, low TFR is associated with significantly higher mortality and lifetime loss. These findings support TFR as a clinically meaningful marker for risk stratification in AS.

Aortic Valve Stenosis