PubMed Health⌕ Search

PubMed · 3013493

Tracheal smooth muscle.

Abstract

Contraction of tracheal smooth muscle requires the binding of Ca2+ to calmodulin, which then binds to and activates MLCK. The Ca2+-calmodulin-MLCK complex catalyzes the phosphorylation of myosin, which causes contraction by stimulating actin-activated Mg2+-ATPase activity of myosin. Myosin phosphorylation appears to be a transient event that is responsible for a high velocity of shortening. The mechanism responsible for maintenance of isometric force is unknown, although a second Ca2+-dependent mechanism with a greater sensitivity to Ca2+ than the activation of MLCK has been hypothesized. Force would be maintained through the slow cycling of nonphosphorylated cross-bridges or a small population of phosphorylated cross-bridges. Tracheal smooth muscle utilizes both extracellular and intracellular pools of Ca2+ for contraction. Moreover, the membrane channels through which extracellular Ca2+ passes have been subdivided into potential-dependent channels (PDCs) and receptor-operated channels (ROCs) independent of membrane potential. The relative extent to which extracellular and intracellular sources of Ca2+ as well as PDCs and ROCs are utilized depends on the agonist used for contraction, its concentration, and the type and location of the smooth muscle being investigated. Calcium antagonists such as verapamil and nifedipine, which reportedly block PDCs but not ROCs, are much better inhibitors of tracheal smooth muscle contractions induced by serotonin than those induced by acetylcholine, histamine, and leukotriene D4, indicating an effect of these latter three agents on ROCs. Relaxation of tracheal smooth muscle following stimulation of beta-adrenergic receptors most likely results from an increase in cAMP that stimulates a cAMP-dependent protein kinase to catalyze a protein phosphorylation that leads to relaxation by decreasing the intracellular concentration of Ca2+. The primary mechanisms whereby cAMP is thought to reduce intracellular Ca2+ to effect relaxation include: activation of a calmodulin-sensitive Ca2+ ATPase in the plasma and sarcoplasmic reticulum membranes, and extrusion of Ca2+ by a Na+-Ca2+ exchange mechanism coupled to Na+-K+-ATPase in the cell membrane. A more controversial mechanism for relaxation that bypasses Ca2+ might involve the dephosphorylation of myosin. Leukotrienes are released by various stimuli, including immunologic challenge, and have been considered as important mediators of bronchoconstriction in allergic asthma.(ABSTRACT TRUNCATED AT 400 WORDS)

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J A Russell. 1986. Tracheal smooth muscle.. https://pubmed.ncbi.nlm.nih.gov/3013493/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of excessive tibial torsion on the capacity of muscles to extend the hip and knee during single-limb stance.

Excessive tibial torsion, a rotational deformity about the long axis of the tibia, is common in patients with cerebral palsy who walk with a crouch gait. Previous research suggests that this deformity may contribute to crouch gait by reducing the capacity of soleus to extend the knee; however, the effects of excess external torsion on the capacity of other muscles to extend the stance limb during walking are unknown. A computer model of the musculoskeletal system was developed to simulate a range of tibial torsion deformities. A dynamic analysis was then performed to determine the effect of these deformities on the capacity of lower limb muscles to extend the hip and knee at body positions corresponding to the single-limb stance phase of a normal gait cycle. Analysis of the model confirmed that excessive external torsion reduces the extension capacity of soleus. In addition, our analysis revealed that several important muscles crossing the hip and knee are also adversely affected by excessive tibial torsion. With a tibial torsion deformity of 30 degrees , the capacities of soleus, posterior gluteus medius, and gluteus maximus to extend both the hip and knee were all reduced by over 10%. Since a tibial torsion deformity reduces the capacity of muscles to extend the hip and knee, it may be a significant contributor to crouch gait, especially when greater than 30 degrees from normal, and thus should be considered by clinicians when making treatment decisions.

Biomechanical Phenomena↗

Predicting the subject-specific primary stability of cementless implants during pre-operative planning: preliminary validation of subject-specific finite-element models.

Pre-operative planning help the surgeon in taking the proper clinical decision. The ultimate goal of this work is to develop numerical models that allow the surgeon to estimate the primary stability during the pre-operative planning session. The present study was aimed to validate finite-element (FE) models accounting for patient and prosthetic size and position as planned by the surgeon. For this purpose, the FE model of a cadaveric femur was generated starting from the CT scan and the anatomical position of a cementless stem derived by a skilled surgeon using a pre-operative CT-based planning simulation software. In-vitro experimental measurements were used as benchmark problem to validate the bone-implant relative micromotions predicted by the patient-specific FE model. A maximum torque in internal rotation of 11.4 Nm was applied to the proximal part of the hip stem. The error on the maximum predicted micromotion was 12% of the peak micromotion measured experimentally. The average error over the entire range of applied torques was only 7% of peak measurement. Hence, the present study confirms that it is possible to accurately predict the level of primary stability achieved for cementless stems using numerical models that account for patient specificity and surgical variability.

Biomechanical Phenomena↗

Experimental validation of intact and implanted distal femur finite element models.

Four finite element (FE) models of intact and distal femur of knee replacements were validated relative to measured bone strains. FE models of linear tetrahedrons were used. Femoral replacements with cemented stemless, cemented and noncemented femoral stems of the PFC Sigma Modular Knee System were analyzed. Bone strains were recorded at ten locations on the cortex. The magnitude of the FE bone strains corresponded to the mean measured strains, with an overall agreement of 10%. Linear regression between the FE and mean experimental strains produced slopes between 0.94 and 1.06 and R(2) values between 0.92 and 0.99. RSME values were less than 12%. The FE models were able to adequately replicate the mechanical behavior of distal femur reconstructions.

Biomechanical Phenomena↗