PubMed Health⌕ Search

PubMed · 3052365

Hepatic trauma.

Abstract

Two hundred thirty-three patients were operated on for hepatic trauma during a two-year period. There were 101 patients with stab wounds, 90 with gunshot wounds, and 42 with blunt trauma. There were 56 isolated liver injuries. Three hundred seventy-five associated injuries occurred among the remaining 177 patients. The majority of patients required only drainage. "Liver sutures" were employed in 66 patients. Only 18 patients required débridement, resection, or packing. Twenty-eight patients (12%) died. Perioperatively, 13 patients died of hemorrhage from the hepatic wound and from the associated major vascular injuries that were present in eight of the 13 cases. The remaining deaths were not primarily a consequence of the hepatic wound. Control of hemorrhage remains the dominant consideration in the treatment of major hepatic wounds.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S C Stain, A E Yellin, A J Donovan. 1988. Hepatic trauma.. https://doi.org/10.1001/archsurg.1988.01400340077013

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Traditional Foley drainage systems--do they drain the bladder?

PURPOSE: Foley catheters are assumed to drain the bladder to completion. Drainage characteristics of Foley catheter systems are poorly understood. To investigate unrecognized retained urine with Foley catheter drainage systems, bladder volumes of hospitalized patients were measured with bladder scan ultrasound volumetrics. Additionally, an in vitro bench top mock bladder and urinary catheter system was developed to understand the etiology of such residual volumes. A novel drainage tube design that optimizes indwelling catheter drainage was also designed. MATERIALS AND METHODS: Bedside bladder ultrasound volumetric studies were performed on patients hospitalized in ward and intensive care unit. If residual urine was identified the drainage tubing was manipulated to facilitate drainage. An ex vivo bladder-urinary catheter model was designed to measure flow rates and pressures within the drainage tubing of a traditional and a novel drainage tube system. RESULTS: A total of 75 patients in the intensive care unit underwent bladder ultrasound volumetrics. Mean residual volume was 96 ml (range 4 to 290). In 75 patients on the hospital ward mean residual volume was 136 ml (range 22 to 647). In the experimental model we found that for every 1 cm in curl height, obstruction pressure increased by 1 cm H2O within the artificial bladder. In contrast, the novel spiral-shaped drainage tube demonstrated rapid (0.5 cc per second), continuous and complete (100%) reservoir drainage in all trials. CONCLUSIONS: Traditional Foley catheter drainage systems evacuate the bladder suboptimally. Outflow obstruction is caused by air-locks that develop within curled redundant drainage tubing segments. The novel drainage tubing design eliminates gravity dependent curls and associated air-locks, optimizes flow, and minimizes residual bladder urine.

Drainage↗