A precision alignment frame for endosseous post dental implants.

Abstract

The advantages of the precision alignment frame are that it (1) accurately positions and aligns the initial pilot drill at implant surgery, (2) has no adverse effects on the diagnostic cast, (3) eliminates the need for an incision or raising a flap when locating a submerged implant root for transmucosal connection, (4) consistently and accurately records the relation of the implant root to the radiograph, (5) permits long-term evaluation of the implant after restoration, (6) has components that are readily obtainable and inexpensive, and (7) is easily made. With a PAF, accurate placement of an implant can be routinely achieved without drill alignment changes. This is especially important when multiple implants are being placed to support a long framework. In most implant sites, the PAF will record the entire image of the implant on the radiograph. However, patients with advanced alveolar bone resorption, flat or narrow vaults in the premaxilla, or high muscle attachments to the mandible may yield only a coronal image of the implant root on the radiograph. In those patients, the PAF is valuable in evaluating early bone healing and remodeling at the permucosal and neck areas.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M O Brose, R Michney, M R Rieger. 1988. A precision alignment frame for endosseous post dental implants.. https://doi.org/10.1016/0022-3913(88)90220-x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Influence of attachment wear on retention of mandibular overdenture.

UNLABELLED: The aims of this study were: (i) to evaluate and compare retention of two-teeth (implant) supported mandibular overdenture with either stud or magnetic attachments during linear (axial) and rotational (paraxial) dislodgements; (ii) to compare retentive properties before and after wear simulation. The test group consisted of five magnetic and four stud overdenture attachments (n = 12 specimens for each attachment type). Retention in axial direction was evaluated on one-tooth (implant) model by measuring maximum retentive force (N) and range of retention (mm) during the linear dislodgement. Retention in the paraxial direction was evaluated on mandibular-overdenture model by measuring the maximum retentive force (N) during three types of rotational dislodgements - anterior, lateral and posterior. The minimum number of cycles required to simulate wear was determined by special wear test. Afterwards, the wear was simulated in the test group, and retention in axial and paraxial directions was measured again. STATISTICAL ANALYSIS: one-way anova, Scheffe post hoc and paired-samples t-tests (P < 0.05). Initially, studs had higher retention (4-11 N) than magnets (4.5-6 N) in axial direction. After the wear simulation, it had decreased from 76% to 48% for some of the studs and had become similar to the retention of magnetic attachments. Magnets had lower retention range (0.2-0.3 mm) than studs (0.5-1.1 mm). Studs provided similar or higher retention in paraxial directions than magnetic attachments both before and after wear simulation. Retentive properties of magnets decreased mostly with posterior rotational dislodgement. Retentive properties of stud overdenture attachments were less constant.

Dental Abutments↗

Transitioning patients from teeth to implants.

One major obstacle to treatment with implants is the transitional phase between a tooth supported occlusion and an implant supported occlusion. This is of particular concern when a patient with a failing dentition has not worn a removable prosthesis before and is planning to have a reconstruction supported by implants.

Dental Abutments↗

Impression techniques for implant dentistry.

The object of making an impression in implant dentistry is to accurately relate an analogue of the implant or implant abutment to the other structures in the dental arch. This is affected by use of an impression coping which is attached to the implant or implant abutment. This impression coping is incorporated in an impression - much as a metal framework is 'picked up' in a remount impression for fixed prosthodontics. With implant copings the coping is usually attached to the implant or abutment with screws. The impression material used is usually an elastomeric impression material; the two types most widely used and shown to be the most appropriate are polyether and polyvinyl siloxane impression materials.

Dental Abutments↗