Techniques for better suturing.

Abstract

Suturing techniques enhancing the accuracy of suture placement and reducing the forces on the tissue being sutured were evaluated in six surgeons, each with 6 years' surgical experience. The accuracy was assessed by the distance between the actual and designated needle exit sites. Force was expressed in terms of the torque on the needle holder using a maximum of the torques (max. F), maximum derivative (dF/dt) and integral (IF). The effects of four factors (suturing techniques) on suturing were evaluated: (1) placement of the needle holder on the needle; (2) inclining the tissue at needle entrance, as is commonly done by elevating with forceps (unnoted role of the forceps); (3) adjustment of the needle's exit during suture placement, as is unknowingly employed in practice, and (4) variation between individual surgeons. All these factors affected the accuracy and force of suturing. Gripping the needle closer to the tip strongly reduced the max. F, dF/dt, and IF per time, as did inclining the tissue. Adjustment of exit improved accuracy, but has the potential for causing avoidable tissue injuries. Differences between surgeons suggest the necessity of addressing fundamental surgical techniques and formally incorporating them into the training programme.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Seki. 1988. Techniques for better suturing.. https://doi.org/10.1002/bjs.1800751212

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A simple model for the function of proteoglycans and collagen in the response to compression of the intervertebral disc.

The nucleus pulposus of the intervertebral disc exerts a pressure which enables it to support axial compression when contained by the annulus fibrosus. The disc was modelled as a thick-walled cylindrical pressure vessel in which the nucleus was contained radially by the annulus. As a result, the stress in the annulus had radial (compressive) as well as tangential (tensile) components. The radial stress at a given point in the annulus was considered to be balanced by the internal pressure which is expected to arise from the attraction of water by proteoglycans. There was a reasonable agreement between the calculated radial stress distribution and published results on the distribution of water within the annulus. As the internal pressure is expected to be isotropic, the annulus was expected to contribute to the axial resistance to compression of the disc; this contribution would be equal, in magnitude, to the radial stress. Predictions of the pressure distribution within the annulus were similar to published experimental measurements made in the radial and axial directions. The tangential stress within the annulus was considered to arise from the restoring stress in its strained collagen fibrils.

Biomechanical Phenomena

Flow-induced prostacyclin production is mediated by a pertussis toxin-sensitive G protein.

Fluid flow and several other agonists induce prostacyclin (PGI2) production in endothelial cells. G proteins mediate the response of a large number of hormones such as histamine, but the transduction pathway of the flow signal is unclear. We found that GDP beta S and pertussis toxin inhibited flow-induced prostacyclin production in human umbilical vein endothelial cells. In addition, flow potentiated the histamine-induced production of PGI2. This suggests that flow stimulates prostacyclin production via a pertussis toxin-sensitive G protein and modulates the stimulus-response coupling of other agonists.

Biomechanical Phenomena