Myocardial function in heart failure.

Abstract

Overt cardiac failure usually presents with constant clinical features as consequences of the reduced pump action, associated with an increased adrenergic drive, independent of the underlying disease. However, the study of left ventricular function, before and during the phase of cardiac insufficiency, shows that different pathophysiological mechanisms are responsible for the symptoms and signs of reduced cardiac action. It is possible to recognize that cardiac failure is caused primarily by: (1) early severe depression of the inotropic state, i.e. dilated cardiomyopathies; (2) late inadequate level of ventricular hypertrophy, with normal contractility, i.e. aortic stenosis; (3) early inadequate level of hypertrophy and slightly reduced inotropic state, i.e. mitral insufficiency, and (4) late inadequate level of hypertrophy and severe progressive reduction in contractility, i.e. aortic insufficiency. The possibility of an 'in vivo' assessment of the different determinant parameters of left ventricular function (contractility, afterload, preload, fiber and chamber compliance) through echocardiography enables a better understanding of the mechanisms leading to the cardiac failure and a more efficient therapeutic approach.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Dalla-Volta, R Razzolini, R Scognamiglio, A Rubino, R Chioin. 1988. Myocardial function in heart failure.. https://doi.org/10.1159/000174438

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Value of exercise echocardiography in rheumatic mitral stenosis with and without significant mitral regurgitation.

Patients with rheumatic mitral valve disease (n = 48) underwent treadmill stress echocardiography and were classified as those with mitral stenosis (n = 24) or those with mitral regurgitation with mild mitral stenosis (n = 24). Despite marked differences in mitral valve area (1.1 +/- 0.3 vs 2.1 +/- 0.6 cm(2), respectively; p <0.0001), systolic tricuspid gradients were similar both at rest (37 +/- 11 vs 37 +/- 13 mm Hg) and at peak exercise (60 +/- 16 vs 55 +/- 13 mm Hg, respectively). Following stress echocardiography, an invasive procedure or modification of medical treatment was performed or recommended in 51% of the study patients.

Echocardiography, Doppler↗

Semirigid partial annuloplasty band allows dynamic mitral annular motion and minimizes valvular gradients: an echocardiographic study.

BACKGROUND: Traditional mitral annuloplasty devices include both rigid rings, which restrict annular motion, and soft rings and bands, which can locally deform. Conflicting data exist regarding their impact on annular dynamics. We studied mitral annuloplasty with a semirigid partial band and with a nearly complete rigid ring. METHODS: Intraoperative three-dimensional transesophageal echocardiograms (n = 14) and predischarge transthoracic echocardiograms were retrospectively analyzed in patients undergoing mitral valve repair for degenerative disease with either a rigid ring (n = 77) or a semirigid partial band (n = 38). Each transesophageal echocardiogram was analyzed with TomTec three-dimensional software to produce cardiac cycle frame planimetry and to measure device geometry. Actual device sizes provided reference dimensions. Blinded analysis of Doppler data from transthoracic echocardiograms was performed. RESULTS: Validation of the quantitative transesophageal echocardiogram methodology revealed a 1.3% +/- 0.3% (mean +/- standard error of the mean) underestimation of actual linear dimension. With the semirigid partial band, systolic valve orifice area and intertrigonal distance decreased from 6.14 +/- 0.37 to 5.55 +/- 0.24 cm(2) (-9.6%; p = 0.01) and from 2.69 +/- 0.08 to 2.55 +/- 0.13 cm (-5.2%; p = 0.03), respectively. Systolic anterior-posterior distance decreased from 2.1 +/- 0.10 to 1.95 +/- 0.06 cm (-7.1%; p = 0.01) compared with diastole. In contrast, rigid ring orifice area was unchanged (4.12 +/- 0.15 to 4.10 +/- 0.16 cm(2); -0.5%; p = 0.48) during the cardiac cycle. Transthoracic echocardiography revealed significantly lower mitral inflow gradients with semirigid partial band (mean gradients compared with rigid ring, 4.0 +/- 0.3 versus 5.0 +/- 0.3 mm Hg; p = 0.02; peak gradients, 8.9 +/- 0.5 versus 11.1 +/- 0.5 mm Hg; p = 0.01). CONCLUSIONS: Three-dimensional transesophageal echocardiographic measurements of annular dynamics are valid and reliable when discrete annuloplasty devices are present. In contrast to the rigid ring, the semirigid partial band permits more physiologic geometric changes and is associated with lower postoperative mitral valve gradients.

Echocardiography, Doppler↗