PubMed HealthSearch

PubMed · 308133

Operator error in multistate myoelectric control systems.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R N Scott, J E Paciga, P A Parker. 1978. Operator error in multistate myoelectric control systems.. https://doi.org/10.1007/bf02442431

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Interface load analysis for computer-aided design of below-knee prosthetic sockets.

A finite-element analysis is made for the compression of soft tissues of the residual lower limb contained in a prosthetic socket. The analysis is relevant to static loading during stance in a patellar-tendon-bearing, below-knee design of socket. Values of Young's modulus are obtained experimentally for use in the model. One of the main objectives is to study the sensitivity of the loading to these values and also to other assumed conditions. Using direct pressure at the limb/socket interface and vertical stiffness as indicators, changes in material properties, socket alignment and socket rectification are investigated; assumptions about the frictional characteristic at the interface are seen to be critical in determination of load distribution. This type of analysis may provide the next stage of refinement for computer-aided socket design systems.

Artificial Limbs

Development of an above-knee prosthesis equipped with a microcomputer-controlled knee joint: first test results.

The shortcomings of conventional above-knee prostheses are due to their lack of adaptive control. Implementation of a microcomputer controlling the knee joint in a passive way has been suggested to enhance the patient's gait comfort, safety and cosmesis. This approach was used in the design of a new prosthetic system for the above-knee amputee, and tested on one patient. The knee joint of a conventional, modular prosthesis was replaced by a knee joint mechanism, equipped with a controllable brake on the knee joint axis. Sensors and a microcomputer were added, keeping the system self-contained. The modularity of the design permits the use of an alternative, external, PC-based control unit, emulating the self-contained one, and offering extended data monitoring and storage facilities. For both units an operating environment was written, including sensor/actuator interfacing and the implementation of a real-time interrupt, executing the control algorithm. A double finite state approach was used in the design of the control algorithm. On a higher level, the mode identification algorithm reveals the patient's intent. Within a specific mode (lower level), the relevant mode control algorithm looks for the current phase within the gait cycle. Within a particular phase, a specific simple control action with the brake replaces normal knee muscle activity. Tests were carried out with one prosthetic patient using a basic control algorithm for level walking, allowing controlled knee flexion during stance phase. The technical feasibility of such a concept is illustrated by the test results, even though only flexion during early stance phase was controlled during the trials.(ABSTRACT TRUNCATED AT 250 WORDS)

Artificial Limbs

A computer-aided socket design procedure for above-knee prostheses.

A computer-aided socket design procedure (CASD) has been developed whereby an above-knee socket shape can be created based on anthropometric measurements taken from an amputee. The anthroometric measurements are used to select a subset of three reference shapes from a Reference Shape Library stored in the computer in the form of three-dimensional numerical data. Transformation procedures then scale the reference shapes at each cross-sectional level to match the amputee's cross-sectional areas. Blending of the three shapes is determined by tissue mass weighting factors, to yield a single custom socket configuration, known as the "basic socket shape." Subsequent graphical procedures in the CASD system allows further sculpting of the shape in the form of interactive adjustments of the numerical data to reach the socket shape desired by the prosthetist. The resultant shape data can then be transferred to a computer numerically controlled (CNC) milling machine to carve a model of the socket shape.

Artificial Limbs