PubMed Health⌕ Search

PubMed · 3114180

Fast neutron therapy for soft tissue sarcoma.

Abstract

Seventy-nine patients with soft tissue sarcoma were treated with fast neutron therapy at the Hammersmith Hospital, MRC Cyclotron Unit. Sixty-six of these, treated between 1971 and 1983 were assessable. The histology was reviewed and graded in 82% of cases and tumors divided into groups according to maximum diameter. In sixteen patients, who were irradiated following complete macroscopic removal of tumor, there was 94% local control and 86% survived 5 years. Of the 50 patients who had gross tumors present 62% were greater than 10 cm in diameter, and 20 were recurrent after previous radiotherapy or surgery or both. Sixty-eight per cent of gross tumors completely regressed and local control was 52%. The main cause of death was metastatic spread, and median survival was 63 months for Grade 1 patients, 9 months for Grade 2, and 7 months for Grade 3. Thus, there was a significant advantage to patients with Grade 1 tumor but little difference between Grades 2 and 3. Twenty-seven patients experienced late complications of treatment, 67% of which involved the skin predominantly and were related to the low energy of neutrons used. Seventeen of the 27 had received previous radiotherapy. Neutron therapy given in this dose and fractionation produced a higher local control rate than photon therapy, but complications were more frequent. Since these mainly involved the skin a lower level of complications may be anticipated using higher energy neutrons which will have a more even distribution of dose and lower skin dosage. Forty-eight per cent of patients developed metastatic disease, indicating the need for effective systemic therapy, especially in Grades 2 and 3 tumors.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D G Pickering, J S Stewart, R Rampling, R D Errington, G Stamp, Y Chia. 1987. Fast neutron therapy for soft tissue sarcoma.. https://doi.org/10.1016/0360-3016(87)90316-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Monte Carlo calculations of thermal neutron capture in gadolinium: a comparison of GEANT4 and MCNP with measurements.

GEANT4 is a Monte Carlo code originally implemented for high-energy physics applications and is well known for particle transport at high energies. The capacity of GEANT4 to simulate neutron transport in the thermal energy region is not equally well known. The aim of this article is to compare MCNP, a code commonly used in low energy neutron transport calculations and GEANT4 with experimental results and select the suitable code for gadolinium neutron capture applications. To account for the thermal neutron scattering from chemically bound atoms [S(alpha,beta)] in biological materials a comparison of thermal neutron fluence in tissue-like poly(methylmethacrylate) phantom is made with MCNP4B, GEANT4 6.0 patch1, and measurements from the neutron capture therapy (NCT) facility at the Studsvik, Sweden. The fluence measurements agreed with MCNP calculated results considering S(alpha,beta). The location of the thermal neutron peak calculated with MCNP without S(alpha,beta) and GEANT4 is shifted by about 0.5 cm towards a shallower depth and is 25%-30% lower in amplitude. Dose distribution from the gadolinium neutron capture reaction is then simulated by MCNP and compared with measured data. The simulations made by MCNP agree well with experimental results. As long as thermal neutron scattering from chemically bound atoms are not included in GEANT4 it is not suitable for NCT applications.

Fast Neutrons↗

Particle matters.

Explore the source record for details and available documents.

Fast Neutrons↗

PIN silicon diode fast neutron detector.

Two batches of diodes, with different structural ratios (the ratio of area and thickness), were made using different manufacturing processes. The energy response of the first batch to 15 kinds of monoenergetic neutrons ranging from 180 keV to 17.56 MeV was tested, and the neutron source response of both batches to 239Pu-Be neutron source was measured. The energy deposition in the diodes irradiated by 1 keV to 20 MeV monoenergetic neutrons was calculated with simulation procedure. The response curve of the experimental results showed an approximately similar trend to that of theoretical computation. Based on the results of the neutron source response experiments, it was concluded that the response of fast neutron varied linearly with the structural ratio of the detectors.

Fast Neutrons↗